The ActivePure® Medical Guardian is designed to reduce airborne contaminants with minimal maintenance.

Filter

:   The ActivePure® Medical Guardian HEPA Filter is replaced when the change filter light illuminates after 180 days 

(approx 6 months) of use.

Cell Module

:  The ActivePure® Medical Guardian ActivePure® Cell is replaced when the change cell light illuminates after 

365 days (1 year) of use. 

The ActivePure® Medical Guardian has a safety shutdown feature to ensure the filter and/or cell replacement is performed 
at the appropriate times. When the filter and/or cell replacement time is reached, the appropriate LED indicator will 
illuminate. However, if the replacement indicator(s) are ignored or if the one or both LED's fail to illuminate, by design 
the device will shut down 3 days of operation after reaching the replacement time. This is to ensure the device does not 
continue to operate with a filter and/or cell past its stated life.

Cabinet

:   Wipe the exterior of the cabinet with a clean, soft cloth as needed to remove finger prints, smudges, etc. Clean 

and disinfect device after each filter change as detailed in the Cleaning/Disinfecting and Filter Replacement 
Instructions.

Important Points:

•     Always unplug device before cleaning

•     Never use gasoline, chemical solvents or any type of corrosive material to prevent damage to the device

•     Use genuine ActivePure Medical® parts to maintain the warranty (See Warranty on Page 11)

SETTINGS

NOTE:

 

Safety switch automatically turns power off when door is opened.

There are four fan settings on the ActivePure® Medical Guardian:

1.      Whisper (one blue light illuminated)

2.      Low (for normal use... two blue lights illuminated)

3.      Medium (for a larger areas... three blue lights illuminated)

4.      High (when maximum airflow is desired... four blue lights illuminated)

When operating the ActivePure® Medical Guardian device for the first time, set the fan speed to the 
highest appropriate speed for the area its placed. Then adjust fan as appropriate for the area if needed.

GENERAL MAINTENANCE INSTRUCTIONS

On/Off

Speed Control

(green light illuminates

  when power is on)

Disconnect power before servicing.

CAUTION:

Содержание F170A

Страница 1: ...1 READ MANUAL CAREFULLY FOR PROPER USE AND OPTIMAL OPERATION MODEL F170A The Aberdeen Bldg 14841 Dallas Parkway Suite 500 Dallas TX 75254...

Страница 2: ...eep cord away from heated surfaces Do not unplug by pulling on cord to unplug grasp the plug to remove not the cord Never handle plug or device with wet hands Keep hair loose clothing fingers and all...

Страница 3: ...vice Specifications 6 Operation 6 Treatment Space 7 Settings 8 General Maintenance Instructions 8 Cleaning Disinfecting and Filter Replacement Instructions 9 ActivePure Cell Replacement Instructions 1...

Страница 4: ...cuit board which controls the device operations and an internal fan to draw air through the device as shown in the general device design Figure 1 Lab test results demonstrated the ActivePure Medical G...

Страница 5: ...atively charged particles which flow out from a series of carbon brushes Carbon to remove odors Hydrophobic polypropylene pleated media filter designed to reduce airborne contaminants Powerful UVGI bu...

Страница 6: ...h 300 CFM 509 m3 h OPERATION DEVICE SPECIFICATIONS Place the ActivePure Medical Guardian in a location that allows air to move freely into around and out of the unit Allow minimum of 12 of clearance a...

Страница 7: ...e Movement of people or equipment within the space Rates of ventilation The device is intended to result in a 4 6 log reduction of airborne microorganisms from initial concentrations in 60 minutes as...

Страница 8: ...r of the cabinet with a clean soft cloth as needed to remove finger prints smudges etc Clean and disinfect device after each filter change as detailed in the Cleaning Disinfecting and Filter Replaceme...

Страница 9: ...hazard sticker 1 plastic bag seal 1 printed copy of instruction for use cleaning disinfecting filter replacement sheet Step 4 Before removing and handling the used filter put on the disposable mask an...

Страница 10: ...of the device If soil is heavy or is still visible repeat step with a new CaviWipe until soil is no longer visible Step 15 Allow the device to dry no visible wetting remains No rinsing is required Wi...

Страница 11: ...at is used for the reduction of staphylococcus epidermidis and erwinia herbicola bacteria MS2 and Phi X174 viruses and aspergillum niger fungal spores and bacillus globigii bacterial spores from the a...

Страница 12: ...des longer fan life Q Why doesn t the display dim immediately when the room gets dark A The automatic dim feature has a brief delay to prevent unnecessary dimming if a shadow momentarily passes in fro...

Страница 13: ...use ActivePure Medical s trademarked names images and logos as well as Internet auction sites e g ebay and Craigslist The only approved Internet presence for ActivePure Medical LLC products is www act...

Страница 14: ...61000 4 11 This device conforms fully to the EMC requirement of IEC 60601 1 2 and is suitable for use in a professional healthcare environment This device is not effected by RFID wireless networks 2...

Страница 15: ...15...

Страница 16: ...vePure Medical LLC The Aberdeen Bldg 14841 Dallas Parkway Suite 500 Dallas TX 75254 1 800 572 0317 ActivePure Medical LLC Canada Inc 3480 Laird Road Suite 2 5 Mississauga ON L5L 5Y4 For information re...

Отзывы: