background image

3    -                                              Rev 1.0 June 2014 

O

VERVIEW

 

Active-Semi’s HYDRA-X10 development platform is a complete hardware solution enabling users not only to 
evaluate the PAC5210 device, but also develop power applications revolving around this powerful and 
versatile Cortex M0 based microcontroller. The module contains a PAC5210 power application microcontroller 
and all the necessary circuitry to properly energize the MCU and its internal peripherals once power is 
applied.  

To aid in the application development The HYDRA-X10 offers access to each and every one of the PAC5210 
device’s signals by means of a series of female header connectors. Whereas the HYDRA-X10 module is 
referred to as the HYDRA-X Body, subsequent daughter card modules can be interfaced through these 
female connectors by merging both boards together. Throughout the rest of this documentation, said 
attachable daughter cards will be referred to as Heads. 

The HYDRA-X10 Body also contains all the necessary circuitry to connect the module to a PC computer 
through a conventional USB port which can then be used in the communication efforts by taking advantage of 
the PAC5210’s UART interface. Graphical User Interface (GUI) software suites can then be used to externally 
control particular application’s features. 

The final block within the HYDRA-X10 Body is a complete Serial Wire Debug (SWD) module which allows the 
microcontroller to be both programmed and debugged in real time. This SWD debugger block follows the 
CoLinkEx architecture and is compatible with the CooCox Integrated Development Environment (IDE). 

Both the USB to UART and SWD debugger can be disconnected from the PAC5210 device in case the user 
wishes to utilize a different means of serial communications or SWD debugging. 

Active-Semi’s HYDRA-X10 Body kit consists of the following:

 

 

HYDRA-X10 Body module

 

 

HYDRA-X10 User’s Guide

 

 

Schematics, BOM and Layout Drawings

 

 

 

Содержание HYDRA-X10

Страница 1: ...Copyright 2014 Active Semi Inc HYDRA X10 Power Application ControllersTM PAC5210 HYDRA X User s Guide www active semi com...

Страница 2: ...ns 5 HYDRA X10 Pinout and Signal Connectivity 5 Power Input 6 Operating the HYDRA X10 Body With 12V VIN 6 LED s 7 SWD Debugging 8 SWD Jumper Shunt and Push Button 8 Serial Communications 9 HYDRA X10 S...

Страница 3: ...tation said attachable daughter cards will be referred to as Heads The HYDRA X10 Body also contains all the necessary circuitry to connect the module to a PC computer through a conventional USB port w...

Страница 4: ...puts I2C UART SPI and GPIO USB 2 UART communication blocks allows communications with a PC computer Integrated SED debugger allows both programming and in real time debugging Foot print compatible wit...

Страница 5: ...ondary SWD port ground GND J2 1 10 Refer to HYDRA X10 pinout diagram J3 1 8 Refer to HYDRA X10 pinout diagram J4 1 20 Refer to HYDRA X10 pinout diagram J5 1 6 Refer to HYDRA X10 pinout diagram J6 1 10...

Страница 6: ...e 16V the system exits UVLO protection and all subsystems including voltage regulators analog front end and microcontroller are enabled When an operational voltage is applied LED D2 will light up This...

Страница 7: ...following table shows the available LEDs and their associated diagnostic function LED Description D1 USB Voltage Lights up when an USB link is present at the J8 connection Driven by the USB s 5V D2 V...

Страница 8: ...obtained by flipping the S2 DIP switches 3 and 4 to the OFF position Figure 4 S2 DIP Switch Debugger Selection The integrated SWD module is powered from the PAC5210 s 3 3V regulator SWD Jumper Shunt a...

Страница 9: ...connection is enabled by default at the factory In the event the user desires to utilize a different serial communications source the S2 DIP switch must be configured to separate the USB 2 UART resour...

Страница 10: ...10 Rev 1 0 June 2014 Figure 6 HYDRA X10 Schematic Diagram...

Страница 11: ...V the PAC5210 s Multi Mode Power Manager will be engaged and the VSYS 5V regulator will be enabled This event will result in LED D2 lighting up 2 Connect the USB Serial Communications to J8 ensure the...

Страница 12: ...icular set of requirements The three prototype heads are named after their size as HYDRA XPROTOS Small size Prototyping Board observes the same footprint as the HYDRA X Body HYDRA XPROTOM Medium size...

Страница 13: ...13 Rev 1 0 June 2014 Figure 10HYDRA X PROTOL Prototype Board 4 x 4...

Страница 14: ...male header connectors to expand the Body module functionality Whereas Active Semi provides a number of existing Heads users can are exhorted to design their own when possible Measurements on where mo...

Страница 15: ...support life critical or safety critical devices systems or equipment nor in applications where failure or malfunction of any Active Semi product can reasonably be expected to result in personal injur...

Страница 16: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Active Semi EP HYDRA X10 1...

Отзывы: