background image

 

 

The Wireless Connectivity Expert 

 

 

921 Corporate Way, Fremont CA 94539 USA 

Tel: +1-510-490-8024    Fax: +1-510-623-7268 

Website: 

http://www.actisys.com/

  E-mail: 

[email protected]

 

ACT-IR100S-L & ACT-IR100SL-M

 

(IrReady

TM

 Intelligent Adapter) 

 

User’s Manual 

 

 

April 22, 2008 

Ver. 1.2.0.1

 

© Copyright 2000-2008 ACTiSYS Corporation 

All Rights Reserved

 

 

Содержание IR100SL

Страница 1: ...4539 USA Tel 1 510 490 8024 Fax 1 510 623 7268 Website http www actisys com E mail irda info actisys com ACT IR100S L ACT IR100SL M IrReady TM Intelligent Adapter User s Manual April 22 2008 Ver 1 2 0...

Страница 2: ...io or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Increase the s...

Страница 3: ...URES 6 2 OVERVIEW 7 3 APPLICATIONS 8 3 2 SIR IrPHY encoder decoder 8 4 OPERATION SETTING EEPROM OTHER OPTIONAL HARDWARE 10 4 1 Serial EEPROM 10 4 2 Baud Rate Setting 11 4 3 Ignore DSR 12 4 4 Ignore CT...

Страница 4: ...ged which is due to the violation of DUT s z Do not expose the unit to moisture as this will damage the internal circuitry z Do not expose the unit to extreme temperatures It should not be placed in d...

Страница 5: ...2 Previous release 1 2 0 1 4 22 2008 Reformatted update Corporate Address ACTiSYS reserves the right to make changes without further notice to any products herein to improve reliability function or de...

Страница 6: ...Mode supported IR100S L Secondary Mode only IR100SL M Both Primary and Secondary Mode supported and mode automatically switched upon IrDA protocol negotiation with the other device Host Interface Full...

Страница 7: ...er device that may benefit from being IrDA enabled The interface between ACT IR100S L LM and the host is via a traditional asynchronous serial data port RS232C Figure 2 1 shows the system block diagra...

Страница 8: ...ace are independent of each other The flow controls of IrDA traffic and host interface are also independent of each other 3 2 SIR IrPHY encoder decoder The ACT IR220VACF chip use in this adapter is an...

Страница 9: ...orp Page 9 of 20 Apr 22 2008 ACTiSYS Confidential Information Version 1 2 0 1 IrLMP and IAS IrLAP IrLPT or IrCOMM 3 wire raw IrCOMM 9 wire TinyTP OBEX Transport TinyTP IrDA Transceiver HOST IrPHY enco...

Страница 10: ...functions if the external serial EEPROM installed The optional serial EEPROM allow users to set Host Speed and Hardware Flow Control and Connection Control The system initial sequence are shown below...

Страница 11: ...this is compatible with end to end data format using 7 data bits parity and 1 stop bit That is the application at both end of the IrDA link may generate and check parity if 7 data bit is used The Host...

Страница 12: ...nection control Active DSR permits IrDA connection Inactive DSR forbids new connection and terminates existing connection Jumper Ignore DSR SEL3 Descriptions NO 0 Ignore DSR input YES 1 DSR is used fo...

Страница 13: ...Note 1 SEL5 SEL6 are reserved for future use 2 Independent of the SEL3 or SEL4 software flow control is automatically used and DTR always active during IrLPT connection this is used for printer host I...

Страница 14: ...Speed and Hardware Flow Control Connection Control The ACT IR100S L LM allowed user to change Host Speed or Hardware Flow Control Connection Control in run time IRSET can change setting and write new...

Страница 15: ...RS 232C DTE DB 9P Connector Pin No Name Descriptions I O 1 CD Data Carrier Detect I 2 RXD Receiver Data I 3 TXD Transmitter Data O 4 DTR Data Terminal Ready O 5 GND Signal Ground GND 6 DSR Data Set Re...

Страница 16: ...VICE IR100S L LM uses a standard RS232 DTE port to connect with the host If the host device is a Modem like device and has a RS232 DCE port then use a straight cable That is connect the signals with t...

Страница 17: ...Apr 22 2008 If the host device is a PC like device and has a RS232 DTE port too then you need to use a Null Modem connection between the two That is in out signal pairs need to be crossed ACTiSYS Conf...

Страница 18: ...API interface well supported z Small code size 4 20K bytes well tested and inter operate with all IrDA devices 100M IrDA Printer Adapter z Attached to and works well with any parallel printers z IR wi...

Страница 19: ...imited warranty described above is in addition to whatever implied warranties may be granted to purchasers by law To the extent permitted by applicable law ALL IMPLIED WARRANTIES INCLUDING THE WARRANT...

Страница 20: ...ight 2000 2008 ACTiSYS Corp Page 20 of 20 Apr 22 2008 8 CONTACT INFORMATION ACTiSYS Corporation 921 Corporate Way Fremont CA 94539 USA TEL 1 510 490 8024 FAX 1 510 623 7268 E Mail irda info actisys co...

Отзывы: