background image

                       

 

 

 

 

The Wireless Connectivity Expert 

 

48511 Warm Springs Blvd., Suite 206, Fremont CA 94539 

Tel: 

+1-510-490-8024

        Fax:

 +1-510-623-7268

 

Website: 

http://www.actisys.com/

  E-mail: 

[email protected]

 

ACT-IR100SD OBEX Server

 

IrReady Intelligent Adapter 

User’s Manual 

 

 

October 30, 2006 

Ver. 1.0 

 

© Copyright 2000-2006 ACTiSYS Corporation

 

All Rights Reserved

 

 

Содержание ACT-IR100SD OBEX Server

Страница 1: ...06 Fremont CA 94539 Tel 1 510 490 8024 Fax 1 510 623 7268 Website http www actisys com E mail irda info actisys com ACT IR100SD OBEX Server IrReady Intelligent Adapter User s Manual October 30 2006 Ver 1 0 Copyright 2000 2006 ACTiSYS Corporation All Rights Reserved ...

Страница 2: ...CT IR100SD 7 4 HOST INTERFACE 8 4 1 Host Interface Signals 9 4 2 RS 232C DTE DB 9P Connector 9 5 OPERATING IN ACT IR100SD 10 5 1 How To Connect IR100SD With Host Device 10 5 2 How To Configure The Role Modes And Other Parameters In ACT IR100SD 10 5 3 OBEX PUT GET Description 14 6 THE DEFAULT SETTING OF ACT IR100SD 16 8 CHARACTERISTICS AND SPECIFICATION 17 Copyright 2000 2006 ACTiSYS Corp Page 2 of...

Страница 3: ...y Expert ACT IR100SD OBEX Server User s Manual REVISION HISTORY Revision History Revision Date Comment 1 0 10 30 2006 Draft Preliminary Design Specification Copyright 2000 2006 ACTiSYS Corp Page 3 of 17 Oct 30 2006 Version 1 0 ...

Страница 4: ... this will damage the internal circuitry Do not expose the unit to extreme temperatures It should not be placed in direct sunlight or in a closed vehicle neither should it be placed near heaters nor other heat sources Do not store the unit in a humid or dusty place Use a soft dry cloth to clean the unit Do not use a wet cloth or any solvent Do not drop the unit or handle the unit carelessly CAUTIO...

Страница 5: ...ch is changeable by PC utility IrDA baud rate from 9 6 kbps to 115 2 kbps which is flexible setting by IrDA devices IR frame and Host buffer are 2048 bytes separately Supply voltage 6 0 V to 12 V Power consumption 20 mA standby 50 mA active Supports 3 wires host interface Tx Rx and GND Interface to Host Full duplex asynchronous serial TXD RXD Hardware flow control RTS CTS Optional line status for ...

Страница 6: ...serial interface with hardware flow control IrDA has two modes one is Primary and the other is Secondary The difference between them is that a Primary mode device initiates discover connection sequence and negotiate IrDA protocol parameters to Secondary mode device while Secondary mode device always waits for commands from Primary mode device Both modes can run different protocols and both may sen...

Страница 7: ...DA user data payload are buffered and then transferred to from the host The baud rates of IrDA traffic and host interface are independent of each other The flow controls of IrDA traffic and host interface are also independent of each other Copyright 2000 2006 ACTiSYS Corp Page 7 of 17 Oct 30 2006 Version 1 0 HOST RS232 converter 75LV737A ACT IR100SD UART1 Buffers IrCOMM 9 wire ACT IR8200D OBEX PUT...

Страница 8: ... RXD Each data byte consists of one start bit 0 8 data bits LSB first MSB last a stop bit 1 and no parity bit Implementing H W flow control signals in host end is recommended Since ACT IR100SD is a buffer limited dongle Without flow control will probably cause data loss sometimes The H W flow control relative signals are DTR RTS DSR and CTS which are defined exactly as RS232 DTE interface 1 1 1 1 ...

Страница 9: ...nabled CTS must be driven active to allow TXD and inactive to forbid TXD If hardware flow control is disabled CTS is optional 5 DSR input If connection control is enabled DSR must be driven active to allow IrDA connection and inactive to forbid a new connection or terminate an existing connection If connection control is disabled DSR is optional 6 DTR output If connection control is enabled active...

Страница 10: ...ready to receive discovery frame from another Primary device outside if IR100SD is set to Secondary mode It depends on what mode is operating in IR100SD When IR100SD is connecting to another IrDA device successfully via IR it will pull DSR signal to high RS232 level which also means that Host can send and receive data frame to and from another IrDA device When DSR is pulled to low it means that IR...

Страница 11: ...s set then it will cause data loss Because no flow control Where data loss can be solved if user sends data by segment and every segment doesn t exceed 2K bytes Ignore DSR If host system has no DSR signals then this bit should be ignored But since this signal triggers IR100SD into Primary mode it will be no way to ask IR100SD disconnecting IrDA link And IR100SD will always be in Primary once power...

Страница 12: ...of discovery and the mode of IR100SD 1 IR100SD supports both Primary and Secondary It allows customer to change it 2 Discovery time should be 3 seconds in general If you want the discovery process faster you can change it 3 Discovery slot can also make discovery process faster Copyright 2000 2006 ACTiSYS Corp Page 12 of 17 Oct 30 2006 Version 1 0 ...

Страница 13: ...less Connectivity Expert ACT IR100SD OBEX Server User s Manual 5 2 3 The third page is to set the IrDA protocols when IR100SD is in Primary Copyright 2000 2006 ACTiSYS Corp Page 13 of 17 Oct 30 2006 Version 1 0 ...

Страница 14: ...ions at the upper half of this figure The protocol part is presented in five rectangles at the lower half of this figure Standard ACT IR100SD doesn t and can t provide the application framework part of OBEX in the wide world of applications the ellipses in Figure The host system using IR100SD must implement that part by host itself Now IR100D OBEX Server provides PUT GET server in OBEX user doesn ...

Страница 15: ...so user s host can t deliver object to cellphone directly The following figure is showing how cellphone or PDA gets some object from user s host They have to give GET command to IR100SD OBEX Server IR100SD OBEX Server will wait data coming from user s host and create response for GET command Cellphone GET an Object IR100SD OBEX server replies HOST device prepare data and form them then send to IR1...

Страница 16: ...uld be 304 6 THE DEFAULT SETTING OF ACT IR100SD The default setting of ACT IR100SD is configured as the following Parameters Setting Host baud rate and data format 115 2 kbps 8N1 DSR CTS Not ignored Device role mode Primary Secondary both Discovery period 3 seconds Discovery slots 6 Primary protocol IrCOMM 9 wire Copyright 2000 2006 ACTiSYS Corp Page 16 of 17 Oct 30 2006 Version 1 0 ...

Страница 17: ...T IR100SD DONGLE DIMENSIONS 8 CHARACTERISTICS AND SPECIFICATION Parameter Min Typical Max Units DC supply voltage 6 0 7 5 12 V Supply voltage VSS 0 V Operating temperature range TA 0 60 DC current Ready mode 40 mA DC current Active mode 50 150 mA Infrared Transmitting range 158 200 cm RS232 signal threshold level 3 6 12 V Version 1 0 ...

Отзывы: