© 2015 Active Research Limited
USB to Serial Gateway - USG-2
Page 9
Using the USB COM Port
Step 1:
Ensure the USB drivers have loaded and determine which COM port your USG-2 has been allocated by the
Operating System (OS). Instructions for how to do this will vary depending on your PC OS, for Windows OS
refer to Device Manager’s ‘Ports’ section.
Step 2:
The COM port must be opened at the same baud rate as the NMEA 0183 device connected to the USG-2.
LED Behaviour
Separating the 2-Part Connector
The two halves of the connector can be separated for ease of installation and for temporary disconnection of devices:
Colour
Blue
Green
Orange
Name
Power indicator
Receive LED
Transmit LED
Function
Illuminates solid blue when
USB driver has successfully
loaded and USB port powered
Flashes to indicate data is
being received on the
USG-2 input
Flashes to indicate data is
being transmitted on the
USG-2 output
Mounting the USG-2
The USG-2 should be installed in a suitable protected location
(e.g. below deck) where it will not come in to direct contact with water.
The USG-2 can be mounted with or without a DIN rail.
DIN rail mounts sold separately.
Accessory product code
DIN-KIT-2
Kit of 1 clip and 2 screws.
Use with USG-2 on top hat (EN 50 022) or G section (EN 50 035) rails
Step 2:
Holding the
orange slider in place,
pull the mated male
header away from the
female connector.
Step 1:
Push the
orange release slider
towards the male
header as far forward
as possible.