background image

NMEA Conversion Gateway - NGW-1   

About

The Actisense NGW-1 NMEA 2000 Gateway is the easiest way to link between a boats old and new data 

networks. The NGW-1 can convert NMEA 0183 data into NMEA 2000 data and vice-versa. 

The NGW-1 is available to purchase in a variety of options: 

NGW-1-ISO is the standard option. With an opto-isolated input and ISO-Drive output for direct NMEA 0183 

device bi-directional connection.  

 

NGW-1-ISO-AIS is the NMEA 0183 AIS option that enables the conversion of NMEA 0183 AIS data 

to its equivalent in NMEA 2000. This provides an ‘out of the box’ solution for quick installation with no 

configuration required.

 

 

NGW-1-USB is the NMEA 0183 USB (1.1 and 2.0) interface for bi-directional connection to a PC for use 

with NMEA 0183 software. 

 

Every option of the NGW-1 is available with the SeaTalkNG to NMEA 2000 adaptor Cable - STNG-A06045. 

The SeaTalkNG to NMEA 2000® adaptor cable (STNG-A06045) is not available as a standalone product 

and must be bought as part of a bundle.  

 

Please go to the 

‘Downloads’

 page of the Actisense website to see the up to date list of conversions the 

various configurations can handle. 

 

 

The Actisense 

NMEA Reader

 software utility allows the NGW-1 user to view and understand (in detail) the 

translated NMEA 0183 sentences output by an NGW-1 directly.

Software Updates

The NGW-1 units have built-in firmware which is held in ‘flash’ memory, allowing quick and easy upgrades 

using the latest NGW-1 ActiPatch.

Actisense recommends that the NGW-1 firmware is kept up to date.  The firmware version currently 

installed on the NGW-1 can be checked on any NMEA 2000 MFD capable of displaying all devices that are 

active on the NMEA 2000 network.  Simply check this number against the latest version number on in the 

downloads

 section of the Actisense website.

Powering the NGW-1

ISO Variants:

All ISO variants of the NGW-1 receive their power supply when connected to a correctly powered 

NMEA 2000 backbone.  The backbone must also be correctly terminated to allow connected devices to 

communicate.  Refer to the “Connecting to an NMEA 2000 Network” section for more information.

USB Variants:

All USB variants will be powered by the PC/laptop USB connection once the USB drivers have been 

successfully installed.  Depending on the settings of the PC/laptop that the NGW-1 is connected to, the 

latest Actisense USB drivers will install automatically from Windows update.  If this does not happen, the 

same USB driver files are available on the CD that is included in the box with the NGW-1 or from the 

NGW-1 

downloads

 web page.    

Содержание NMEA NGW-1-ISO

Страница 1: ...NMEA Conversion Gateway Install User Manual For all variants NGW 1 ISO NGW 1 ISO AIS NGW 1 STNG NGW 1 USB Issue 3 0...

Страница 2: ...ing to a PC laptop 6 LED Behaviour and Troubleshooting 7 Changing Firmware 8 Configuring using NMEA Reader 9 Connecting the NGW 1 to NMEA Reader 9 Changing the Baud rate 9 Selecting PGNs for Conversio...

Страница 3: ...rd party caused by the use of information or drawings described in this manual Product registration Please register your product via the online form on www actisense com Your product package includes...

Страница 4: ...llows the NGW 1 user to view and understand in detail the translated NMEA 0183 sentences output by an NGW 1 directly Software Updates The NGW 1 units have built in firmware which is held in flash memo...

Страница 5: ...nt Drop Power T NMEA 2000 Device NMEA 0183 Network NMEA 2000 Pin Out The diagram below illustrates the standard wiring colours used by all NMEA 2000 devices like the NGW 1 NGW 1 NMEA 2000 Network NET...

Страница 6: ...s of any NMEA 0183 Talker Listener NGW 1 Do not connect NMEA Listener In NMEA Talker Out B A B A GND TX GND RX NMEA 0183 DEVICE Arrows indicate direction of data flow Wire Colour Label Connnects To Bl...

Страница 7: ...start up these LEDs will flash alternately and very quickly for 2 seconds The primary function of the NGW 1 NMEA 0183 LED is to indicate reception of a valid NMEA 0183 sentence The NMEA 2000 LEDs mai...

Страница 8: ...232 port on it Please refer to Connnecting to a PC laptop on page 6 2 You might want to consider our Actisense DB9 F and USB 1 products if do not have cables already 3 For a quick and easy connection...

Страница 9: ...rmware NMEA Reader will attempt to communicate with the NGW 1 Once successful the Hardware Config tab will become available and the green LED indicator next to the Baud selection will flash Note You m...

Страница 10: ...turns on or off the special Actisense system status sentences from the 0183 output The default is the permanently disabled to conserve output bandwidth Once you have selected the new behaviour click A...

Страница 11: ...software To view a list of software that can be used with the NGT 1 please visit our NGT 1 compatibility page If using the ISO variant of the NGT 1 please contact the software developer to ensure tha...

Страница 12: ...Drive 20mA max Output Protection Short circuit and ESD Input Voltage Tolerance 15V to 15V continuous 35V to 35V short term 1 second Input Protection Current limited and overdrive protection to 40VDC...

Страница 13: ...ateway pre configured with AIS conversions NGW 1 STNG NMEA 0183 to SeaTalk NG Gateway NGW 1 USB NMEA 0183 to NMEA 2000 Gateway with USB standard configuration STNG A06045 SeaTalkNG to NMEA 2000 adapto...

Отзывы: