background image

General Safety Information

1.  Always carefully read, thoroughly understand and follow the pump operating instructions. Use this pump correctly and with 

care for the purpose for which it is intended. Failure to do so may cause damage or personal injury, and will void the
warranty. Please retain instructions for future reference.

2.  Contact your chemical or fluid supplier to check for compatibility with pump prior to installation and operation.
3.  Prior to use, always carefully and thoroughly read and understand the OSHA information contained in the MSDS sheet
     supplied for the chemical which is to be pumped.
4.  Wear protective clothing (goggles, face mask, long sleeves, long pants, gloves, aprons, etc) as set forth in the OSHA

Safety Data Sheet when pumping any hazardous chemicals.

5.  When using flammable liquids, pump containers should be grounded to avoid static electricity.
6.  Any pump used for transferring flammable liquids must be stored in a ventilated area after use.
7.  Pump should be washed out before it is used since processing lubricants may contaminate the fluids.

8. Prior to use, inspect your pump thoroughly verifying its proper assembly.

9.  If pump is removed from drum, it should be thoroughly rinsed in a liquid that is compatible with the pump.

Operating Instructions & Parts Manual for Model 6008

This pump is designed to fit 5, 15, 30 & 55 gallon drums with 3/4" and 2" threaded openings, and also 2-5/8"
flexspout openings for 5-gallon pails. The extension tubes included can reach the bottom of a 55 gallon
drum. The pump is adjustable to pump 2, 4, 6 or 8 oz per stroke. It has a polypropylene exterior body and polyethylene
internal parts. The pump is commonly used for pumping water, water-based liquids and detergents.

Specifications

Flow rate per stroke. . . . . . . . . . . . . . . . . . . . . . . . . 2, 4, 6 or 8 oz
Mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 gal. flex 2-5/8"
Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2"
Outlet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/2"
Bung Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2"  &  3/4" PP

Suction Tube (Length & Material). . . . . . . . . . . . . . .32" PE

Packing Gland. . . . . . . . . . . . . . . . . . . . . . . . . . . . .  PE
Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  PE & PP
Viscosity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 cps
Max. Temp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  140°F

Revised 04/01/2004

using hose clamp (Ref. No. 20).

2. Attach discharge spout (Ref. No. 15)

1. Check to see if all parts are present.

Installation

nut.

pump leaks at the top replace packing

Normal maintenance is not required. If

Maintenance

supplier.

compatibility, contact your chemical

fluid. For questions about chemical

compatible with both the pump and

thoroughly in liquid that is

3. If pump is removed from drum, rinse

15) to prevent dripping.

(Ref. No. 16) on end spout (Ref. No.

2. When finished pumping, place cap

leakage. 

Tighten only enough to prevent

NOTE:

top of pump. 

tighten packing nut (Ref. No. 2) on

If slight leakage should occur, simply

flowing on second or third upstroke.

operation. Liquids should begin

1. The pump is now ready for

Operation

down.

snap off making sure to hold pail

pail, pull towards side of pail and

4. To remove pump with adapter from

snap over the other side.

Insert tube extension into side, then

and remove diaphragm (Ref. B).

3. Remove cap on FLEXSPOUT closure

13). Tightly secure adapter.

threads at bottom of pump (Ref. No.

2. Screw adapter (Ref. No. 14) on male

flexspout closures.

designed to fit senior (metal ring)

1. This adapter (Ref. No. 14) is

PAIL ADAPTER INSTALLATION

spigot.

stand to the side or in back of the

operating the pump, you should

rotated to desired location; when

8. Entire pump head (Ref. No. 4) can be

drum.

No. 18) can be cut to fit specific

7. For various size drums, tubing (Ref.

to limit pump stroke.

(Ref. No. 9 or Ref. No. 11) over rod

top grip (Ref. No. 1) and slide tubing

6. To adjust pump delivery, unscrew

tighten.

5. Insert pump into opening and hand

10). 

and secure with hose clamp (Ref. No.

4. Attach extension tubing to (Ref. A)

17) and two clamps (Ref. No. 20).

by using tube connector (Ref. No.

3. Join two lengths of extension tubing

Exploded parts view on reverse side