21
3.4.10 Connecting Cables Drive Units
Assemble the following components:
#
Part name
Qty
21
Power supply
1
22
Power cord
1
23
Link cable drive unit
1
24
Cable keypad
1
25
Keypad up-dowm
1
Photo 30
Connect the Link cable (extra long from Extension set) with the connector in the Slave
drive unit. The original Link cable (#23) will not be used.
Photo 31
Connect the other end of the Link cable to the correct connector in the Master drive
unit.
Connect the Keypad Cable to the Keypad and the correct connector of the Master drive
unit.
Connect the Power supply Cable to the correct connector of the Master drive unit.
Make sure that the course of the cables is always unobstructed! Tighten the cables to
the top crossbars or top supports with tape or cable binders (not included).
Photo 32
Connect the power cord to the power supply and stick the plug in to the electricity
socket (115-230 V~, 50-60Hz).
32
30
Motor link cable
SLAVE
31
Powersupply
Cable up/down switch
Motor link cable
MASTER