Scope_manual_en-v110.docx
— 42 —
Fig.97
– Multi-Diag Scope as ohmmeter when no measurement
probe is connected (figure applies to version 7.2.4)
Fig.98
– Multi Diag Scope as ohmmeter when bad measurement
probe is connected (figure applies to version 7.2.4)
14.5.3
CONDUCTIVITY TEST
Conductivity test
– Ohmmeter operates in the measurement mode of small resistances not exceeding 15 Ohms.
The measuring is accompanied by tone beeping (by means of a PC sound card).
Measured resistance value
Tone beeping
0 to 5 Ohms
continuous beep
5 to 15 Ohms
interrupted beep
over 15 Ohm
without beep, the message “Circuit open” is displayed
Fig. 99
– Multi-Diag Scope in the conductivity test mode (figure applies to version 7.2.4)
14.5.4
DIODE MEASUREMENT
Diode
test
– it is designed for the control of the semiconductor junction of diodes both in the forward and reverse
directions.