Web Interface
© 2018 ACTIA I+ME GmbH │ Ref. IR:14938
65
/
92
12.5.5.1
Automatic Restart
The automatic relaying indicates whether the playback on the monitor is done as per
the data in >Cycle controls< or not.
0 Switching Input 8 to high level causes a relay in the sequence as
per the settings in the cycle controls. The current display remains
active for about 10 seconds after the high level in digital input 8
drops. After that, the default video input is displa yed.
1 The video sources are displayed as per the specifications in the
cycle controls.
12.5.5.2
Cycle Controls
The individual sequence segments are divided by a comma. The total sequence is
repeated in a cycle when >Automatic relaying< is enabled.
V.. = video input / multiscreen selection
v1 .. v16 = single screen display of the specified video channel
v20 .. v23 = multiscreen display
t.. = display duration