ACTi Z83 Скачать руководство пользователя страница 5

www.acti.com

Hardware Manual 

                 

Safety Instructions 

Cleaning 

Disconnect this video product from the power supply before cleaning. 

 

Attachments 

Do not use attachments not recommended by the video product manufacturer as they may cause 

hazards. 

 

Water and Moisture 

Install other devices (such as PoE injector, alarm, etc.) that will be used with the camera in a dry 

place protected from water. 

 

Servicing   

Do not attempt to service this video product yourself as opening or removing covers may expose 

you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. 

 

Damage Requiring service 

Disconnect this video product from the power supply immediately and refer servicing to qualified 

service personnel under the following conditions. 

1)  When the power-supply cord or plug is damaged 

2)  If liquid has been spilled, or objects have fallen into the video product. 

3)  If the video product has been directly exposed to rain or water.   

4)  If the video product does not operate normally by following the operating Instructions in this 

manual. Adjust only those controls that are covered by the instruction manual, as an improper 

adjustment of other controls may result in damage, and will often require extensive work by a 

qualified technician to restore the video product to its normal operation. 

 

Safety Check 

Upon completion of any service or repairs to this video product, ask the service technician to 

perform safety 

checks to determine if the video product is in proper operating condition. 

 

 

 

Never look at the transmit laser while the power is on. Never look 

directly at the fiber ports and the fiber cable ends when they are 

powered on. 

 

Use of controls or adjustments to the performance or procedures 

other than those specified herein may result in hazardous laser 

emissions. 

 

Содержание Z83

Страница 1: ...Outdoor Zoom Dome Hardware Manual Z83 Z84 Ver 2020 04 16...

Страница 2: ...te the Cables 12 Step 3 Mount the Camera 13 Step 4 Connect and Manage the Cables 14 Using the Cable Gland 14 Using a Power Adapter Optional 17 Step 5 Connect to Network 17 Step 6 Access the Camera Liv...

Страница 3: ...attempt to service this video device yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Trademarks All names...

Страница 4: ...ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction...

Страница 5: ...is damaged 2 If liquid has been spilled or objects have fallen into the video product 3 If the video product has been directly exposed to rain or water 4 If the video product does not operate normall...

Страница 6: ...oduction List of Models This hardware manual contains the following models Z83 2MP Outdoor Zoom Dome with D N Adaptive IR Superior WDR SLLS 4 3x Zoom lens Z84 4MP Outdoor Mini Dome with D N Adaptive I...

Страница 7: ...ver Drill Template Quick Guide Warranty Card IMPORTANT When the camera is taken out from the box the lens cover is covered by a thin film DO NOT remove this film It is used to protect the lens cover f...

Страница 8: ...ot included See Using a Power Adapter Optional Error Reference source not found on page 17 for more information 2 Ethernet Port Connects to a network using an Ethernet cable with RJ 45 connector 3 Res...

Страница 9: ...Mount optional mounting accessory is required for this type of installation Pendant Mount Suitable when installing the camera on high ceilings where a straight tube is used to lower the camera The Pen...

Страница 10: ...cable will go through a hole on the surface or be routed along the surface Note also the direction to which the cable will be routed to attach the bundled drill template on the surface according to t...

Страница 11: ...r NOTE The dome cover is attached to the camera body by a safety strap do not abruptly lift the dome cover 5 If a memory card will be used for local recording insert the card into the slot at this poi...

Страница 12: ...a NOTE If the camera will be installed outdoors or in places wherein environmental factors change drastically make sure to waterproof the cable connection see Step 4 Connect and Manage the Cables on p...

Страница 13: ...era 1 Mount the camera to the surface using the three 2 bundled screws 2 Pan and adjust the camera tilt angle as needed Rotate horizontally to pan the camera Loosen the screw to tilt the camera lens R...

Страница 14: ...roof tape to protect other cable connections For other cable connections such as a power adapter see Using a Power Adapter Optional on page 17 for more details DISCLAIMER ACTi will not be responsible...

Страница 15: ...Hardware Manual 15 3 Insert the clamping nut into the Ethernet cable 4 Insert the sealing insert through the Ethernet cable 5 Insert the cable through the gland body 6 Push the sealing insert into th...

Страница 16: ...the camera connector 8 Attach the gland body to the camera connector 9 Attach the clamping nut to the gland body to complete the cable solution NOTE Make sure the clamping nut is tightly attached to...

Страница 17: ...he connector rubber cover if this connecter will not be used Wrap the cable connectors with waterproof tape if the cable connections will be exposed outdoors Step 5 Connect to Network Connect the othe...

Страница 18: ...e Manual 18 Step 7 Adjust the Viewing Angle and Orientation Step 8 Close the Dome Cover Rotate horizontally to pan the camera Loosen the screw to tilt the camera lens Rotate horizontally to rotate the...

Страница 19: ...mediately be ready for the access from the PC The user however might not know the IP address of the camera yet It is necessary to know the IP address of the camera in other to be able to access it by...

Страница 20: ...work and it does not detect any DHCP services it will automatically assign itself a default IP 192 168 0 100 Whereas the default port number would be 80 In order to access that camera the IP address o...

Страница 21: ...P Utility With the procedure shown above all the cameras will have unique IP addresses starting from 192 168 0 101 In case there are 20 cameras selected the last one of the cameras would have the IP 1...

Страница 22: ...eps to turn off UAC Click the Start button and then go to Control Panel In the search box type UAC then click Change User Acount Control Settings Move the slider to Never Notify position and then clic...

Страница 23: ...www acti com Hardware Manual 23 Before logging in you need to setup the root Account and Password of the camera Then use this newly setup Account and Password to login to the Web Configurator...

Страница 24: ...Copyright 2020 ACTi Corporation All Rights Reserved 7F No 1 Alley 20 Lane 407 Sec 2 Ti Ding Blvd Neihu District Taipei Taiwan 114 R O C TEL 886 2 2656 2588 FAX 886 2 2656 2599 Email sales acti com...

Отзывы: