background image

Acterna TestPad

Base Station & Air Interface Test Module (BAT)

Getting Started Guide

Содержание TestPad

Страница 1: ...Acterna TestPad Base Station Air Interface Test Module BAT Getting Started Guide...

Страница 2: ...d for repair Acterna s Air Interface Instruments and network systems are recognized leaders in their field and are deployed around the world Acterna s R D labs are actively developing testing solution...

Страница 3: ...0 Power LEDs 11 Handle with pocket for stylus 11 Table for absolute power and reflection 12 Connectors 13 Slot for PCMCIA cards 14 Printer port 14 Switches and connectors 15 Battery slot 15 Three Main...

Страница 4: ...4 Up and Downloading Configuration Data and Reports 27 Service and Calibration 27 Federal Communications Commission FCC Notice 28 Industry Canada Notice 28 Publication History 31...

Страница 5: ...pgrades So your feedback can be the first step towards an improved ver sion of the BAT Send us your comments you can reach us by email fax or via our local sales offices Additional information hints a...

Страница 6: ...d in the operating manual which is included with the BAT Module in the form of detailed online help This booklet will provide you with initial information and guide you up to the point where you will...

Страница 7: ...b 2 RF cables N type on N type connectors 2 m ca 6 ft long one with a blue cap and one with a yellow cap c 2 RF adapter cables N type to SMA connectors one marked blue one marked yellow d 1 high band...

Страница 8: ...d comes with a Getting Started Guide of its own please refer to this when unpacking and installing the TestPad The complete tester consists of the BAT Module and the Acterna TestPad 2000TM The latter...

Страница 9: ...lide the BAT Module into the Acterna TestPad 2000TM Tighten the screw with a coin Power on the TestPad The application software will be downloaded from the BAT Module this will take a few minutes Your...

Страница 10: ...he BAT Module consists of the following user elements a Power LEDs b Connectors c Table for absolute power and reflection d Switches and connectors e Battery slot f Handle with stylus pocket g PCMCIA...

Страница 11: ...hat the battery is be ing charged LOW BATTERY LED lights up when battery charge is low Handle with pocket for stylus Power LEDs Handle for carrying the TestPad The stylus can be used to operate the us...

Страница 12: ...nversion table for power and reflec tion measurements is printed on the right hand side of the front panel of the module If you want to convert between different dimensions please use the equations be...

Страница 13: ...r the attenuated radio output or the coupled forward power Note The short antenna is for PCS high band measurements and the long antenna with two colored rings is for cellular low band measurements Co...

Страница 14: ...eeds to be ATA compatible An external PCMCIA storage device is highly recommended if you want to store many screenshots The printer port is also used to up and download the base station configuration...

Страница 15: ...ernal DC supply and to charge your battery 0 1 This switch is used to turn the power on and off Handset The BAT module does not make use of the Hand set connector Battery slot Note With some versions...

Страница 16: ...ng the BAT Application 1 Measurements at the base station s attenuated output Attach one end of the blue cable to the Main connector of the BAT and the other end to the attenuated RF output of the bas...

Страница 17: ...arrier frequency Carrier frequency error Warning Always use the attenuated output Never connect the high power output of the radio directly to the BAT A direct connection can be hazardous and may dest...

Страница 18: ...and Coupler order code AC 016953 This device if of high accuracy and superior to many couplers built into base stations Connect one end of the blue cable to the Main connector of the BAT and the other...

Страница 19: ...lication you can measure Output level Output spectrum Output power ripple Carrier frequency error Reflected power antenna match Frequency dependent reflected power Taking measurements using a bidirect...

Страница 20: ...ation You can cover all the fre quencies in which the base station transmits or receives by using the two antennas included in the standard delivery Attach the respective antenna to the Antenna connec...

Страница 21: ...band With this application you can test The RF environment of the base station Emitted field strength Emitted spectrum Neighboring base stations Interference on the forward link downlink The RF envir...

Страница 22: ...hat you use the stylus supplied with the TestPad to activate functions on the screen you can also lightly touch the screen with any blunt object or with your finger When you power the module the main...

Страница 23: ...are the System and Application button sec tions which are described on the following pages Application buttons Configure Using the Configure application you can enter your location verify or reconfigu...

Страница 24: ...t Press this button to check the output power alignment including ripple detection Power is measured in actual values dBm This application is used for measuring the signal reflection If you want to me...

Страница 25: ...asic system setup allowing you to enter parameters such as user name date and time storage loca tion for screenshots and reports sound volume and brightness You can also view the equip ment revisions...

Страница 26: ...help screen The online help will guide you in operating the BAT It can be called up by pressing the question mark on the screen The help screens contain all information that you need to proceed with...

Страница 27: ...Calibration The BAT can only be repaired by Acterna s trained service engi neers Each repair requires a new calibration of the BAT to ensure measurement accuracy The BAT should be recalibra ted at lea...

Страница 28: ...sidential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with part 15 of the FCC Rules Operati...

Страница 29: ...This page has been left blank intentionally...

Страница 30: ...This page has been left blank intentionally...

Страница 31: ...n any form or by any means printing photocopying or any other method without the express written permission of Acterna M nchen GmbH Acterna Acterna M nchen GmbH Wireless Technical Assistance Center Wi...

Страница 32: ...o SP Brasil Tel 55 11 5503 3800 Fax 55 11 5505 1598 Asia Pacific 42 Clarendon Street PO Box 141 South Melbourne Victoria 3205 Australia Tel 61 3 9690 6700 Fax 61 3 9690 6750 Western Europe Arbachtalst...

Отзывы: