Acterna FST-2000 TestPad Скачать руководство пользователя страница 3

Loading application module software upgrades

June 2004

FST-2000 TestPad Service Pack/Upgrade/Optioning Instructions

3

5

Turn the TestPad power ON.
A series of boot-up screens appear as the TestPad powers on, 
loads the service pack, and then automatically reboots.

When the main screen appears, the service pack is loaded.

Loading application module software upgrades

The following procedure describes how to load an application module 
software upgrade. Loading a software upgrade can take up to one 
hour.

To load an application module software upgrade

1

Make sure the application module is properly connected to the 
UIM.

2

Make sure the TestPad is OFF.

3

Connect the AC adaptor that shipped with your UIM to the 
TestPad, and then plug the adaptor into a power source.

4

Do one of the following:
– Insert the PCMCIA card with the software upgrade into one of 

the PCMCIA card slots located on the unit’s top panel.

– If you previously downloaded the software upgrade on to the 

TestPad, you do not need to insert a PCMCIA card. Proceed to 

step 5

.

5

Turn the TestPad power ON.
A series of boot-up screens appear as the TestPad powers on, 
followed by a dialog box informing you that a newer version of 
software has been detected for the application module. The dialog 
box prompts you to upgrade the software.

6

Respond to the prompts as directed.
After all upgrade files are loaded, the TestPad automatically 
reboots, and the main screen appears.

The application module software upgrade is loaded.

Содержание FST-2000 TestPad

Страница 1: ...rades for FST 2000 TestPad application modules that are compatible with Version 6 V6 and Version 3 V3 user interface modules UIMs Topics covered in this document include the following Getting started on page 2 Loading a V6 UIM service pack on page 2 Loading application module software upgrades on page 3 Loading options for V6 compatible application modules on page 4 Loading options for V3 compatib...

Страница 2: ...ing a battery charged to at least 50 percent capacity as a backup power supply Loading a V6 UIM service pack The following procedure describes how to load a service pack for a V6 UIM To load a service pack 1 Make sure the application module is connected to the UIM 2 Make sure the TestPad is OFF 3 Connect the AC adaptor that shipped with your UIM to the TestPad and then plug the adaptor into a powe...

Страница 3: ...stPad is OFF 3 Connect the AC adaptor that shipped with your UIM to the TestPad and then plug the adaptor into a power source 4 Do one of the following Insert the PCMCIA card with the software upgrade into one of the PCMCIA card slots located on the unit s top panel If you previously downloaded the software upgrade on to the TestPad you do not need to insert a PCMCIA card Proceed to step 5 5 Turn ...

Страница 4: ... loading the options See step 6 of Loading application module software upgrades on page 3 3 Select the Tools button and then do one of the following To load UIM options select TestPad Settings and then select the Revisions Options tab To load application module options select FST XXXX Settings where XXXX represents the module number for example FST 2310 The Revisions Options tab appears Options cu...

Страница 5: ...hipped on the card Before you begin loading options make sure the TestPad battery is charged to at least 50 percent As a backup power supply make sure the unit connected to an AC power adaptor that is plugged in To load options on a V3 compatible application module 1 Make sure the TestPad is OFF 2 Make sure the application module is properly connected to a Version 3 UIM 3 Insert the PCMCIA card wi...

Страница 6: ...st and Management Solutions and its logo are trademarks of Acterna LLC All other trademarks and registered trademarks are the property of their respective owners Specifications terms and conditions are subject to change without notice Technical assistance If you need assistance loading the service pack upgrades or options contact Acterna s Technical Assistance Center TAC at 1 800 638 2049 You can ...

Отзывы: