Troubleshooting: how to diagnose problems and remedy them.

Problem

Cause

Solution

Poor evacuation.
The aspiropulsor is connected and the
water supply is open but the evacuation
doesn't work.

1/ The outpipe is blocked or bent.
2/ An inappropriate object has been
thrown in the bowl and is blocking the
turbine.
3/ The condenser on the motor is
malfunctioning.
4/ The thermal security is activated.
5/ The electronic cycle is defectuous
6/ A fuse has blown.

1/ Check the outlet pipe.

3/ Open the inspection hatch and remove the object.

4/ Change the condenser.
5/ Allow the motor to cool for 5 to 10 minutes.
6/ Change the condenser.

Nothing happens when the push-button is
pressed.

1/ The transparent tube is detached.

2/ Power cut.
3/ Problem in the electronic cycle.
4/ The pressostat is malfunctioning.

1/ Verify and reconnect it, verify the connection of the
pneumatic button.
2/ Test the power supply.
3/ Change the timer control.
4/ Change the pressostat..

The aspiropulsor functions but the water
doesn't flow.

1/ Problem in the water inlet
2/ Blocked filter on the turbine

3/ Turbine malfunctioning
4/ Problem in the electronic cycle.

1/ Verify the water supply at the tap.
2/ Unscrew the "stop-shock" tube and clean the filter.
3/ Change the turbine
4/ Change the timer control

The water cycle fails to stop

1/ Turbine malfunctioning.

2/ Defect in the electronic cycle control.

1/ If after disconnecting the power supply the water
continues to flow, change the turbine.

2/ If the water stops flowing, change the timer control.

At the end of the cycle the water level is not
restored

1/ Siphoning

1/ Put on air gape on the waste pipe.

Water leak in the rinsing.

1/ Too much pressure on the water
supply.

1/ Interpose a reducer of pressure to bring the pressure
to 3 bars maxi.
2/ Verify the good fitting of the pipe of rinsing.

The cycle sees out systematically
continuously.

1/ Defective electronic cycle.

1/ Change the timer.

The aspiropulser works only during 1 or 2
seconds.

1/ Defective electronic cycle.

2/ Defective thermic protection.

1/ Change the timer.

2/ Change the aspiropulser.