A10 Operating and Installation Instructions

0

Relay time

5s

1

Door 2 / Output 2 time

5s

2

Output 3 time

5s

3

Door Ajar time

30s

4

Guest Buzzer time

2s

Option

Function

Default

Operation

30

Door Chime

Off

When set, whenever the door contact is opened, the built-in buzzer makes a
chime sound and the buzzer output activates for 2 seconds.

31

Silent Operation

Off

When set, the keypad operates silently, that is no audible tones (key-presses
or confirm tones) are produced from the built-in buzzer function (function 0).

32

Permanent

On

When set (default), the keypad illumination is always on. This option will

Backlighting

override option 42 (Auto backlighting)

33

Locksaver

Off

When set, and when the relay is active (following a valid code or buttonr elease),

(Anti Tailgating)

the relay timer is truncated to 2 seconds when the door contact opens. This
ensures that irrespective of programmed relay time, the door will be locked
as soon as it closes, and any person following will have to enter a code.

34

Alarm

Off

When set, the keypad may be used as a remote keypad for an alarm system. The red

Keypad

and green indicators are controlled by the door contact and the release button inputs

Operation

inputs respectively, and the built in buzzer is controlled by the interlock input.

35

Interlock

Off

When set, two or more keypads may be interlocked so that only one controlled
door may be open at any one time. The interlock output is active whenever the
relay is active or when the door contact is open. When the interlock input is
active the release button and all codes are inactive, and the red indicator flashes.
The interlock outputs and inputs of any number of keypads may be combined
on a single wire.

36

Six Digit Codes

Off

When set, all user codes, and the programming code, are six digits long. The

Codes

default user one code becomes 123456 and the default programmer code
becomes 999999.

37

Twin Codes

Off

When set, two different codes must be entered within 15 seconds in order to
open the door. The outputs activated are those which have been programmed
for the first code to be entered.

Timer No.

Function

Default

Timers may be set to any duration between 2 seconds and 4 minutes.

Setting Configuration:

(From programming mode)
Enter

30-37 or 40-47

(Option number)

0-1

(1= Set, 0 = Unset)

7

Содержание ENTRY A10

Страница 1: ...ACT entry A10 Operating Installation Instructions 18 00044 ...

Страница 2: ...maximum Operating Temperature 10 to 50 degrees C Door Open Time 0 4 minutes Relay Contact Rating 5A 50Vac Controller Size Flush Mount 378 x 144 x 11mm Surface Mount 358 x 125 x 38mm Water Resistance Medium IP54 Ordering Information Vandal Resistant Door Entry Panel with integrated ACT 10 Digital Keypad Call Button and Speech Unit in a Surface Mount Kit Door Intercom Handset Power Supply Vandal Res...

Страница 3: ...ACTentry A10 Operating and Installation Instructions 3 ACTentry A10 Schematic ...

Страница 4: ... new programming code 4 digits e g Change a Programming Code to 9876 9999 0 tick 9876 4 Exit Programming Mode On the digital keypad press button The yellow LED indicator stops flashing Programming code has been exited The ACTentry A10 is now ready for normal use Test the operation of the code Note The ACTentry A10 may be returned to its factory default condition at any time by entering the program...

Страница 5: ...ordance with the wiring diagram below The door entry panel is supplied with either a surface or shelteredlocation Cable Requirements For optimum speech clarity it is strongly recommended that the ACTentry A10 system is installed using twisted pair telephone cable eg type CW1308 Use one of the pairs for the R O connection between the speech unit and the telephone intercom handset Connections Core d...

Страница 6: ... user Default user codes Programming 9999 99 User 1 1234 56 All others inactive Setting switched output combinations From programming mode Enter 1 Set Outputs 0 9 User number 0 9 0 7 Output function code Output Function Code Door Output Door 2 Output 2 Output 3 Default function code is 1 Relay Timed for all users When the door is toggled open this will be For example to set user 1 to toggle the do...

Страница 7: ...ed as a remote keypad for an alarm system The red Keypad and green indicators are controlled by the door contact and the release button inputs Operation inputs respectively and the built in buzzer is controlled by the interlock input 35 Interlock Off When set two or more keypads may be interlocked so that only one controlled door may be open at any one time The interlock output is active whenever ...

Страница 8: ...ghting response to any key being pressed or while in programming mode This option is overridden by option 32 permanent backlighting To prevent any illumination unset options 32 and 42 43 Door Ajar Off When set and the door contact has been open for longer than the time programmed Alarm into the door ajar timer the built in and external buzzers sound intermittently The buzzers may be silenced by cl...

Страница 9: ...he feedback threshold Check your wiring for this fault 4 The Door Entry Panel and the Door Intercom Handset are too close together You should not be able to hear the caller without the use of the Door Intercom Handset 5 The Door Entry Panel is surrounded by reflecting walls e g a basement flat In this situation acoustic feedback may occur at lower volume levels It may be necessary to change the po...

Страница 10: ...Push Door Contact Button TAMPER LK1 N C N O C RELAY DOOR 2 OMRON 5A 250V AC 5A 30VDC I RO T Z DoorIntercom Handset base of Speech Unit Volume A Adjust Volume B Adjust Call Button ACT 10 Keypad Volt Free Tamper Contacts Run O and R as twisted pair V 0V V V 0V ACTentryA10 Operating and Installation Instructions Rear View T y p i c a l A C Te n t r g u r a t i o n Energised Lock C H R O T Amaximumof4...

Страница 11: ...12 AC DC N C N O C 0V Buzzer OP3 Duress OP2 Interlock OUTPUTS INPUTS 0V Interlock PB2 Push Door Contact Button TAMPER LK1 N C N O C RELAY DOOR 2 OMRON 5A 250V AC 5A 30VDC I RO T Z DoorIntercom Handset base of Speech Unit Volume A Adjust Volume B Adjust Call Button ACT 10 Keypad Volt Free Tamper Contacts Run O and R as twisted pair V 0V V V 0V Rear View T y p i c a l A C Te n t r g u r a t i o n De...

Страница 12: ...y Business Centre Tallaght Dublin 24 Ireland Tel 353 1 4662570 Fax 353 1 4520427 UK Locall 0845 300 5204 Web http www accesscontrol ie E mail tech accesscontrol ie Copyright 2008 Access Control Technology Ltd User List ...

Отзывы: