ACTentry
A10 Operating and Installation Instructions
0
Relay time
5s
1
Door 2 / Output 2 time
5s
2
Output 3 time
5s
3
Door Ajar time
30s
4
Guest Buzzer time
2s
Option
Function
Default
Operation
30
Door Chime
Off
When set, whenever the door contact is opened, the built-in buzzer makes a
chime sound and the buzzer output activates for 2 seconds.
31
Silent Operation
Off
When set, the keypad operates silently, that is no audible tones (key-presses
or confirm tones) are produced from the built-in buzzer function (function 0).
32
Permanent
On
When set (default), the keypad illumination is always on. This option will
Backlighting
override option 42 (Auto backlighting)
33
Locksaver
Off
When set, and when the relay is active (following a valid code or buttonr elease),
(Anti Tailgating)
the relay timer is truncated to 2 seconds when the door contact opens. This
ensures that irrespective of programmed relay time, the door will be locked
as soon as it closes, and any person following will have to enter a code.
34
Alarm
Off
When set, the keypad may be used as a remote keypad for an alarm system. The red
Keypad
and green indicators are controlled by the door contact and the release button inputs
Operation
inputs respectively, and the built in buzzer is controlled by the interlock input.
35
Interlock
Off
When set, two or more keypads may be interlocked so that only one controlled
door may be open at any one time. The interlock output is active whenever the
relay is active or when the door contact is open. When the interlock input is
active the release button and all codes are inactive, and the red indicator flashes.
The interlock outputs and inputs of any number of keypads may be combined
on a single wire.
36
Six Digit Codes
Off
When set, all user codes, and the programming code, are six digits long. The
Codes
default user one code becomes 123456 and the default programmer code
becomes 999999.
37
Twin Codes
Off
When set, two different codes must be entered within 15 seconds in order to
open the door. The outputs activated are those which have been programmed
for the first code to be entered.
Timer No.
Function
Default
Timers may be set to any duration between 2 seconds and 4 minutes.
Setting Configuration:
(From programming mode)
Enter
30-37 or 40-47
(Option number)
0-1
(1= Set, 0 = Unset)
7