Operating & Installation Instructions for
ACTpro MIFARE Classic Readers
18-00070
Страница 1: ...Operating Installation Instructions for ACTpro MIFARE Classic Readers 18 00070 ...
Страница 2: ...INFORMATION 2 READER OUTPUT DATA FORMAT 3 WIRING INFORMATION FOR CLOCK DATA OUTPUT 3 WIRING INFORMATION FOR WIEGAND OUTPUT 4 READER CONFIGURATION 5 OPERATION 5 SECTOR READER 5 SERIAL AND REVERSE SERIAL READER 5 BACKLIGHT OPERATION 5 READER CONFIGURATION 6 POWER ON BEEP CODES 6 READER REPROGRAMMING 7 MOUNTING INSTRUCTIONS 8 MIFARE PANEL MOUNT INSTALLATION 9 1 ...
Страница 3: ...on Sector Serial or reverse serial Product Specification MIFARE 1030 MIFARE 1030PM MIFARE 1040 MIFARE 1050 Description MIFARE Classic proximity reader MIFARE Classic proximity reader MIFARE Classic proximity reader MIFARE Classic pin and proximity reader Mounting Mullion Panel Surface Flush Proximity Yes Pin No Yes Outputs Clock Data or Wiegand 37bit 32bit and 26bit Yes Selectable sector serial re...
Страница 4: ... 26bit Wiegand output using a programming card Wiring Information for Clock Data Output The standard Clock Data wiring colours for ACTpro MIFARE Classic readers are shown below Reader PIN Description Recommended wiring colour Description Sense White Direction connect for entry Clock D1 Green Clock D1 Data D0 Blue Data D0 12 24 V DC Red Voltage 0 V Black Voltage Red Brown Red LED Green Yellow Green...
Страница 5: ...hite Direction connect for entry Clock D1 Green Clock D1 Data D0 Blue Data D0 12 24 V DC Red Voltage 0 V Black Voltage Red Brown Red LED Green Yellow Green LED Wiring for Entry Exit Wiegand Readers Wiring for Wiegand Entry Reader Colour Controller Pin White 0V Green CLOCK D1 Blue DATA D0 Red 12V Black 0V Brown RED Yellow GREEN Wiring for Wiegand Exit Reader Colour Controller Pin White 0V Green CLO...
Страница 6: ...Tpro MIFARE classic 1030 is selectable via cable configuration the default setting is Sector where both Orange and Purple cables are connected to 0V To change the operation down power the reader change the Orange and Purple cable for the desired operation and reapply power Colour Sector Serial Reverse Serial Orange 0V 0V Not Connected Purple 0V Not Connected 0V Sector Reader The default sector rea...
Страница 7: ...ing 0V to the Buzz PIN The buzzer activates 4 seconds after the 0V is applied and sounds continuously until the 0V is removed External Buzzer Control not available on the ACTpro MIFARE 1030 reader The Red and Green LED are activated by applying 0V to the respective Red and Green input pins Power On Beep Codes The Output Data Format and the Sector Serial Operation of the reader can be determined by...
Страница 8: ...rmation on how the existing cards are encoded before generating the programming card To reprogram an ACTpro MIFARE reader the programming card must be presented to the ACTpro MIFARE reader after power up and while the LED is Red The ACTpro MIFARE will acknowledge the re programming by playing an ascending note tune The configuration is held in non volatile memory and so is held even if the reader ...
Страница 9: ...ACTpro MIFARE classic Operating and Installation Manual Rev 1 0 Mounting Instructions Flush Mount Unit Surface Mount Unit 8 ...
Страница 10: ...ARE classic Operating and Installation Manual Rev 1 0 9 Installation diagram for MIFARE Panel Mount Reader Rear view of the ACTpro MIFARE Panel Mount reader connection to the ACTpro Door Controllers Door Stations ...