Installation and Configuration Instructions for the ACTpro IOM Input/Output Module
9
Copyright © 2016 Access Control Technology Ltd. Part No.18-00039 Issue 2.0
Inputs can be enabled by timezone and when an output is on. If any inputs are unused,
simply set the Time Zone to Not Active and the Output to No Output. For example, you
may want the input to be monitored only during the day or only when a particular output is
on.
The input may be set to activate an output or to open a door.
The Normally Open option allows the input to be in the normal state when the contact is
open and active when the contact is closed.
If the Supervised option is checked, then two 4k7 resistors are required (see the wiring
diagram at the end of the manual). This allows the IOM to check for tampers and shorts
across the input contacts.