ACTpro 1520 PSU Operating and Installation Manual  

 

 

 

   

 

LED indicators: 

 

Green - 

AC OK

 

Indicates that the AC Mains is within specification. 

Amber 

– 

Powered By Battery

  Indicates that the battery is supplying the output voltage. 

Red - 

Fuse Fault

 

Indicates electronic output shutdown fuse is active and 
that no power is being supplied to the load. 

The maximum current that the PSU can guarantee is 2A. 
Beyond this the fuse will trip and the LED will stay on until 
the load is fully disconnected. 

Once the load has been disconnected, remove devices to 
reduce the current demand below 2A.  

It is important for the installer to calculate the power 
budget adequately. Please refer to the section titled 
„Power Budget‟ for more information. 

Installation Instructions: 

 

The ACTpro 1520 is for indoor installation only and must be installed as permanently 
connected equipment. 

This equipment must be earthed and an RCD/Earth Fault device must be fitted. 

An external disconnect device must be fitted. Before installation ensure that the mains 
supply to the ACTpro 1520 is disconnected. 

Mains power should be connected to the ACTpro 1520 by a licensed electrician in 
accordance with local/national codes. 

Mounting. 

 

Mount the ACTpro 1520 directly on to the wall with the supplied screws.  

The keyed mounting hole should be screwed first to the wall to aid the mounting.  The unit 
should be installed in a ventilated area that allows for accessibility after installation. 

Содержание ACTpro 1520

Страница 1: ...18 00084 ACTpro 1520 Single Door IP Controller with 12 V DC 2A power supply PSU Operating Installation Instructions...

Страница 2: ...le every effort has been taken by ACT to ensure the accuracy of the information contained within this document ACT assumes no responsibility for any errors or omissions No liability is assumed for dam...

Страница 3: ...oups 250 Time Zones 250 Door Groups 250 Log Events 5000 Browser Compatibility Microsoft Internet Explorer 8 or 9 Firefox Version 8 0 Relay contact rating Main relay 5A 50 Vac AUX relay 1A 50 Vac Indoo...

Страница 4: ...Output Voltage 12V DC The power supply provides two 12V outputs One pre wired to power the ACTpro 1500 controller The full load current of 2A is shared between the two outputs However the total curre...

Страница 5: ...the power budget adequately Please refer to the section titled Power Budget for more information Installation Instructions The ACTpro 1520 is for indoor installation only and must be installed as per...

Страница 6: ...y Amber led illuminated If the Amber led is illuminated the battery is now supplying the output Re apply the mains power the AC OK Led will illuminate and the Power By Battery led will extinguish Powe...

Страница 7: ...ted ACTpro MIFARE 1050e ACT RFID Surface Flush PIN proximity reader IP67 ACTpro MIFARE 1060e ACT PIN only reader ACTpro X MIFARE 1030PM Panel mount multi format proximity reader IP67 ACTpro 1030e VR V...

Страница 8: ...ct Details Tel 353 1 4662570 UK LoCall 0845 300 5204 Fax 353 1 4662570 Web www accesscontrol ie E mail tech accesscontrol ie E mail sales accesscontrol ie Certifications The ACTpro 1520 complies with...

Отзывы: