ACTentry A5 Operating and Installation Manual
Rev 1.1
Relay Timers
Relay timers are set in the factory to 5 seconds. Timers may be set to any duration between 2 seconds and 4
minutes.
Step Keypad Entry
Operation
1
xxxx
Enter Programming Mode
2
2
Set Relay Timers
3
0-1
0 For Relay 1, 1 for Relay 2. {Buzzer sounds indicating timing…wait
required period}
4
(Stop timing){Buzzer stops – timer set}
Example: To set Relay 1 time to 10 seconds press:
9999 2 0 ...wait 10 seconds, then
Relay Configuration
The Output Function code is assigned to a user. For example, one user could be assigned to open Relay 1 and
another user could be assigned to open Relay 2. Default function code is 1 (Relay 1 Timed) for all users (all users
only activate Relay 1).
Output Function Code
Relay 1
Relay 2
0
Toggled
1(Default)
Timed
2
Timed
3
Timed
Timed
When the door is toggled open, this will be indicated by the CALL indicator flashing.
Step Keypad Entry
Operation
Example: set User 7 to toggle the Relay open/locked
1
xxxx
Enter Programming Mode
9999
Enter Programming Mode
2 1
Set
Outputs
1
Set Outputs
3
0-9
Enter User Number 0-9
7
User 7
4
0-3
Enter ‘Output Function Code’
0
Toggled
Example: Set User 7 to toggle Relay 1 (open/locked) press:
9999 1 7 0
Example: Set User 6 to open Relay 2 press:
9999 1 6 2
Example: Set User 5 to open Relays 1 and 2 press:
9999 1 5 3
12