DO
silcone all screw mounting positions and cable entry.
DO install a weather shield when the keypad is
1. installed on an uneven surface
2. in an exposed area
DO apply silicone to the top and two sides of the keypad, or shield, when used.
DO NOT apply silicone to the bottom of the keypad as this will block the air
vents and trap any water which may enter the keypad
If a weather shield is fitted the same applies
Figure 2: ACT10 Digital Keypad_Guide to outdoor installation in exposed areas
Figure 1: ACT10 Digital Keypad Schematic
PSU
EXIT
220/240 Volts AC
Tamper
3 Inputs (100mA)
3 Outputs (100mA)
12/24 Volts AC/DC
ACT 10 Digital Keypad Operating & Installation Instructions
7
Figure 2: ACT 10 Digital Keypad Schematic
Figure 3: ACT 10 Digital Keypad - Guide to outdoor installation in exposed areas