Fig. 1 Control Panel 

3.3 

Control Panel: 

3.3.1 

High-Off-Low Switch to start and select the speed of the unit 

3.3.2 

Push Button Breaker 20 Amp 

3.3.3 

Power Supply (PS) Receptacle 15 Amp 

3.3.4 

Pressure Gauge 

3.3.5 

Sensing Port 

3.4 

Turning unit 

On

3.4.1 

The switch must be in off position, before connecting the power supply.

 

3.4.2 

The main switch is located on the control panel (see fig. 1) and is a three position 
switch (High-Off-Low). Push the switch to the right to operate in low speed or to the 
left to operate in high speed, the middle position is off.  

3.5 

Turning unit 

Off

3.5.1 

To turn the unit off, set the switch to the middle position. 

3.5.2 

At the end of the project, the filters should not be removed, instead the intake 
opening should be sealed with polyethylene film and duct tape.  

High-Off-Low Switch 

Breaker 20 Amp 

Pressure Gauge 

PS Receptacle 

Sensing Port 

Содержание FA2000EC

Страница 1: ...GHT ROAD HOUSTON TEXAS 77075 PHONE 713 987 0336 FAX 713 987 0355 www acsi us com FORCED AIR 2000EC PORTABLE HEPA FILTRATION UNIT PART ORDER NUMBER FA2000EC OPERATING MAINTENANCE MANUAL DOCUMENT NUMBER OPMM 001E R0 ...

Страница 2: ...FA2000EC LD R1 Ladder Diagram INDEX 1 GENERAL INFORMATION 2 DIMENSIONS 3 OPERATION 4 FILTRATION 5 FILTER REPLACEMENT 6 ELECTRICAL SCHEMATIC 7 LADDER DIAGRAM 8 REPLACEMENT PARTS LIST 1 GENERAL INFORMATION 1 1 The FORCED AIR 2000EC PORTABLE HEPA FILTRATION UNIT is designed for indoor use and to provide the most efficient air filtration with three stages of filtration The first stage Pre filter Pad r...

Страница 3: ...th for proper operation If more than 50 ft is needed please consult with your distributor Reducing the required cord size gauge or increasing the length of the cord will increase the amperage and can damage the 15 amp power supply receptacle 3 1 3 3 1 4 The unit needs to be grounded properly including the ground pin on the plug Keep electrical cords away from water and do not use a damaged cord 3 ...

Страница 4: ... 3 3 5 Sensing Port 3 4 Turning unit On 3 4 1 The switch must be in off position before connecting the power supply 3 4 2 The main switch is located on the control panel see fig 1 and is a three position switch High Off Low Push the switch to the right to operate in low speed or to the left to operate in high speed the middle position is off 3 5 Turning unit Off 3 5 1 To turn the unit off set the ...

Страница 5: ...d see fig 2 is recommended to be changed as it becomes loaded and the airflow capacity of the unit decreases or the pressure gauge at the control panel exceeds 2 6 inches at high speed or 1 9 inches at low speed of W C see fig 1 4 2 Second Stage Filter Ring Panel Filter 4 2 1 24 x 24 x 1 4 2 2 Triple Ply Ring Panel 4 2 3 Removes particles up to 1 micron and larger from the air flowing through the ...

Страница 6: ...tions 4 4 Proper disposal of filters is described in Section 5 4 of this manual 5 FILTER REPLACEMENTS 5 1 Pre filter Pad Replacement 5 1 1 Turn the FA2000EC unit off and make sure to disconnect the power supply cord from the unit 5 1 2 Open the door and remove the contaminated pre filter pad 5 1 3 Fold in the sides of the contaminated pad and dispose of as per section 5 4 5 1 4 Install a new pre f...

Страница 7: ...C off and make sure to disconnect the power supply cord from the unit 5 3 2 Open the door and remove the ring panel filters as described in section 5 2 5 3 3 Remove the HEPA filter by loosening the four nuts and rotating the tabs to the open position 5 3 4 Pull the HEPA filter out of the cabinet and dispose of as per section 5 4 5 3 5 Inspect the gasket on the new HEPA filter housing before instal...

Страница 8: ...tive equipment and follow safe work practices as per applicable regulations 6 REPLACEMENT PARTS LIST Item Part Number Descriptions 1 76012802 Blower Motor 1 75 HP 2 76252002 Blower for FA2000 3 38900423 FA2000 Motor Blower Assembly 4 72650102 Capacitor 35uF 370VAC 50 60Hz 5 Call Dist HEPA Filter 24 x 24 x 11 5 6 Call Dist Ring Panel Filter 24 x 24 x 1 7 Call Dist Pre filter Pad 24 x 24 x 1 8 32000...

Отзывы: