![ACS Thermocont TS4L Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/acs/thermocont-ts4l/thermocont-ts4l_technical-manual_2841825025.webp)
ACS-CONTROL-SYSTEM GmbH l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]
25
7 .5 Environmental conditions
Environmental temperature
-40°C...+85°C
Protection
IP65/IP67 (EN/IEC 60529)
Climatic classification
4K4H (EN/IEC 60721-3-4)
Shock classification
50g [11ms] (EN/IEC 60068-2-27)
Vibration classification
10g (L1/L2 ≤ 100mm) [10…2000 Hz] (EN/IEC 60068-2-6)
2g (L1/L2 > 100mm) [10…2000 Hz] (EN/IEC 60068-2-6)
EM compatibility
Operation device class B / Industrial range (EN/IEC 61326)
Tightening torque
Process connection type 6
≥ 5Nm … ≤ 20Nm
Weight
0,35kg (L1=100mm/L2=0mm)
7 .6 Materials - process wetted
Sensor tube
Steel 1.4404/316L
Steel 1.4571/316Ti
Process connection
Steel 1.4404/316L
Steel 1.4571/316Ti
Surface quality
Ra < 0,8µm
7 .7 Materials - not process wetted
Neck tube
CrNi-steel
Terminal enclosure
CrNi-steel
Control panel surface
PES
Electrical connection part
Device plug PUR
Pressure compensation element Acrylic copolymer
Gaskets
FPM – fluorelastomere (e.g. Viton
®
)
Содержание Thermocont TS4L
Страница 32: ......