CommStat4 Modbus Interface I&O Manual 12/2021 rev. 5

 

 

This manual describes the steps to install and operate the Marvair

®

 CommStat

 4 Modbus Interface Adapter.  This 

device provides both Ethernet and serial interfaces to allow a remote system to read and write parameters to the 
CommStat

 4 controller through the Modus TCP or Modbus RTU communications protocol.

 

 

The following materials are provided in the Modbus Interface Adapter package: 

  Modbus Interface Adapter device 

  Installation and Operations Manual (this manual) 

 

The following materials should be provided by the installer: 

  Laptop with Windows 7, 8, or 10 to configure the IP address of the Modbus Interface Adapter 

  Mechanical and electrical installation hand tools (wire cutters & strippers, drill, drill bits) 

 

Important Safety Information 

1.

 

Turn Electrical Power OFF at the breaker or fuse box BEFORE installing or working on the Modbus adapter. LINE 
VOLTAGES ARE HAZARDOUS or LETHAL.

 

2.

 

OBSERVE and COMPLY with ALL applicable ELECTRICAL AND BUILDING CODES and ORDINACES.

 

3.

 

INSTALLATION and SERVICE should be performed ONLY by QUALIFIED and EXPERIENCED PEOPLE.

 

4.

 

USE COMMON SENSE and 

BE SAFETY CONSCIOUS

.

 

This is the safety alert symbol.   

When you see this symbol in the manual, be alert to the potential for personnel 

injury or equipment damage. Understand the signal word DANGER, WARNING and CAUTION. These words are 
used to identify levels of the seriousness of the hazard. 

 

DANGER

 

Failure to comply will result in death or severe personal injury and/or property damage.

 

 

 

WARNING

 

Failure to comply could result in death or severe personal injury and/or property damage.

 

 

 

CAUTION

 

Failure to comply could result in minor personal injury and/or property damage.

 

 

IMPORTANT 

is used to point out helpful suggestions that will result in improved installation, reliability or operation.

 

 

Confidentiality: 

This document and the information contained in it are confidential and are the property of Marvair

®

. It may not in 

any way be disclosed, copied or used by anyone except as expressly authorized by Marvair

®

. The document should 

always be kept in a secure place and should be destroyed or returned to Marvair

®

 when it is no longer needed. Not 

for use or disclosure, except under written agreement. © 2021 Marvair

®

 Proprietary. All rights reserved. 

 

 

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 

© 12/2021 

Marvair

®

, An AirX Climate Solutions Brand

 

 

 

Содержание Marvair CommStat 4

Страница 1: ...AirX Climate Solutions Brand P O Box 400 Cordele Georgia 31010 156 Seedling Drive Cordele Georgia 31015 229 273 3636 Fax 229 273 5154 E mail marvairsales airxcs com Internet www marvair com The most...

Страница 2: ...and EXPERIENCED PEOPLE 4 USE COMMON SENSE and BE SAFETY CONSCIOUS This is the safety alert symbol When you see this symbol in the manual be alert to the potential for personnel injury or equipment da...

Страница 3: ...not exceed 15ft 457cm including all necessary conduit routing Note that the adapter must be installed inside the shelter it is not suitable for installation either inside an HVAC unit or where exposur...

Страница 4: ...CommStat 4 Modbus Adapter Installation Operation Page 4 Figure 1 Modbus Interface Adapter External Connections Figure 2 Modbus Interface Adapter Power LED...

Страница 5: ...1 19 If a different IP address is required a laptop can be used to re configure the adapter In order to establish communications the laptop must have and IP address within the same subnet as the adapt...

Страница 6: ...Installation Operation Page 6 Click Change adapter settings Figure 5 Network and Sharing Center Right click on the Local Area Connection and select Properties from the drop down menu Figure 6 Local A...

Страница 7: ...pdated Click Use the following IP address and enter 192 168 1 100 in the IP address field and 255 255 255 0 in the Subnet mask field Do not enter any values into any of the other IP address fields The...

Страница 8: ...anges The adapter will reboot and after 60 seconds the new network configuration will be active Note that if the new network parameters are on a different subnet the browser will lose communications t...

Страница 9: ...aster Setting 12 Stage 1 Differential See CommStatTM 4 manual 40014 Master Setting 13 Stage 2 differential See CommStatTM 4 manual 40015 Master Setting 14 Off differential See CommStatTM 4 manual 4001...

Страница 10: ...slave unit 1 Self explanatory See note 3 40050 Master Output command master to slave unit 2 Self explanatory See note 3 40051 Master Saved value of master unit 1 outputs Self explanatory Internal Use...

Страница 11: ...3 Bit 7 is always clear if bit 6 is set this unit is outputting to Y if bit 5 is set this unit is outputting to 2 if bit 4 is set this unit is outputting to O if bit 3 is set this unit is outputting t...

Страница 12: ...e is 12 it is in stage 0 if value is 13 it is in stage 1 heating if value is 14 it is in stage 2 heating if value is 15 it is in stage 3 heating if value is 16 it is in stage 4 heating 6 If bit 7 is s...

Страница 13: ...igh voltage input enable alarm output enable 40111 Remote Setting 11 Anti short cycle timer 40112 Remote Setting 12 Stage 1 Differential 40113 Remote Setting 13 Stage 2 differential 40114 Remote Setti...

Страница 14: ...rd 40143 Remote Function code The purpose of this communication signal Table 2 CommStat 4 Modbus Write Registers The process to update parameters in the CommStat 4 unit is controlled through the use o...

Страница 15: ...ABS Thermoplastic flammability rating UL94 5VA External Connections Power Supply Terminal Block The two position power input terminal block has the following connections Wire Color Label Description B...

Страница 16: ...el 1 NC 2 Ground 3 RS 485 RX TX A 4 RS 485 RX TX B 5 VCC 6 NC Figure 13 RJ11 Connector Pinout Ethernet RJ45 Connector The female RJ45 socket provides the Ethernet connection for the Master system The...

Страница 17: ...CommStat 4 Modbus Adapter Installation Operation Page 17 Dimensional Drawings Figure 15 Adapter Enclosure Dimensions 1...

Страница 18: ...CommStat 4 Modbus Adapter Installation Operation Page 18 Figure 16 Adapter Enclosure Dimensions 2...

Отзывы: