APG8201-B2
– Reference Manual
Version 1.00
www.acs.com.hk
Page 23 of 48
www.acs.com
.hk
7.2. Reader to PC
7.2.1.
RDR_to_PC_DataBlock
This
message
is
sent
by
APG8201-B2
in
response
to
the
command
message
PC_to_RDR_IccPowerOn
,
PC_to_RDR_XfrBlock
and
PC_to_RDR_Secure
.
Offset
Field
Size
Value
Description
0
bMessageType
1
80h
Indicates that a data block is being sent
from the CCID
1
dwLength
4
-
Size of
abData
field of this message
5
bSlot
1
-
Identifies the slot number for this
command, Same value as in Bulk-OUT
message
6
bSeq
1
-
Sequence number for the corresponding
command, Same value as in Bulk-OUT
message.
7
bStatus
1
-
Slot status register
8
bError
1
-
Slot error register
9
bChainParameter
1
00h
RFU (TPDU exchange level)
10
abData
Byte
array
-
This field contains the data returned by
the CCID
7.2.2.
RDR_to_PC_SlotStatus
This
message
is
sent
by
APG8201-B2
in
response
to
the
command
message
PC_to_RDR_IccPowerOff
.
Offset
Field
Size
Value
Description
0
bMessageType
1
81h
-
1
dwLength
4
00000000h
Message-specific data length
5
bSlot
1
-
Identifies the slot number for this
command, Same value as in Bulk-
OUT message
6
bSeq
1
-
Sequence number for the
corresponding command. Same
value as in Bulk-OUT message.
7
bStatus
1
-
Slot status register
8
bError
1
-
Slot error register
9
bClockStatus
1
00h, 01h,
02h, 03h
Value:
00h = Clock running
01h = Clock stopped in state L
02h = Clock stopped in state H
03h = Clock stopped in an unknown
state
All other values are RFU.