INSTALLATION MANUAL
6
CAMERA REMOVAL
NOTE: This process detailed below should be completed concurrently with the “Device
Removal” process described in section 22.0 of the LR installation and services manual
(60-000249).
1.
In the
Service
menu, scroll to the
Removal
option and press
Select
. The handset
screen will display
“Insert USB drive”
.
2.
Insert the USB drive into the USB cable (13-001144). Once the USB drive is
connected and detected by the camera, the image transfer from the camera
memory begins automatically.
NOTE: If the USB key still has files from previous use, the handset screen will display
“USB drive contains data”. Choose the “Delete” option to clear the USB. Image
transfer will then begin.
3.
Once the image transfer has begun and is in progress, continue the standard
removal procedure. Once completed, the handset will display
“Removal
Complete Connect to PC”
.
NOTE: If the standard removal procedure is completed before the image transfer has
completed, a message will appear on the handset indicating that more time is needed.
4.
Remove the USB drive and disconnect the handset. Proceed with ITE Removal
Transaction outlined in section 22.5 of the LR installation and services manual
(60-000249).
5.
Remove heat shrink and unsolder all wire and ground connection of the camera
Power Harness Cable.
6.
Remove camera from mounting surface and use alcohol wipe to eliminate any
residue.
NOTE: If all images are not downloaded from the camera memory during the removal
process, the camera must be sent back to ACS for picture retrieval. The camera will not
allow re-installation to another vehicle prior to being sent back to ACS.
CAMERA EXCHANGE
If the camera is diagnosed as not able to take a picture or communicate during the
install or monitor procedure, an error message will be displayed on the handset screen
followed by a prompt to connect a new camera. Only use new cameras from ACS or
cameras which have been fully cleared of all previous images prior to start installing.
Cameras with files still on them should be sent back to ACS as soon as possible for
retrieval.
In the case of physical damage to a camera, there is an opportunity to exchange the
camera with a new one before the
“Connect to PC”
message appears during the
Install or Monitor procedures.