background image

 

7.2.4. 

EXCHANGE_T1_FRAME 

To exchange an APDU (Application Protocol Data Unit) command/response pair between the MCU 
card inserted in the BioCARDKey and the host computer using T1 protocol. 

Command format 

Instruction 

Code 

Data length 

Data 

 

LEN 

T1 BLOCK 

FRAME 

A1 

H

 

 

 

LEN

 

 

Length of APDU command data, N 

DATA

   

T1 Block frame to be sent to the card 

Response data format 

BYTE 1 

... 

... 

BYTE N 

 

 

 

 

BYTE x

  

Response T1 Block from card (if any)  

Document Title Here 

Document Title Here 

Document Title Here

 

AET60 Reference Manual 

Version 1.7  

 

Page 21 of 24

 

[email protected] 

www.acs.com.hk 

Содержание AET60 BioCARDKey

Страница 1: ...AET60 BioCARDKey Reference Manual Subject to change without prior notice info acs com hk www acs com hk...

Страница 2: ...se Length 255 bytes 11 6 2 2 No Transmission Error with Extended Response 12 6 2 3 Transmission Error 12 6 3 Reset Message 13 6 4 Card Status Message 13 6 5 Transmission Protocol 14 7 0 Smart Card Com...

Страница 3: ...e that no one else can use their smart card should it become lost or stolen In the present state of the smart card industry different types of smart cards use different commands and different communic...

Страница 4: ...biometric application 1 Enrollment Before the identity of an individual can be verified via his her fingerprints it is necessary to capture one or several fingerprint samples This process is called e...

Страница 5: ...ecifications of ISO7816 3 with certain restrictions or enhancements to increase the practical functionality of the BioCARDKey 3 2 1 Smart Card Power Supply VCC C1 The current consumption of the insert...

Страница 6: ...being removed As a general rule however to avoid any electrical damage a card should only be removed from the reader while it is powered down NOTE The BioCARDKey never does by itself switch on the pow...

Страница 7: ...ed along with the device Status LEDs Red LED on the front of the reader indicate the activation status of the smart card interface Red LED Indicates power supply to the smart card is switched on i e t...

Страница 8: ...upply for the reader 2 D Differential signal transmits data between BioCARDKey and PC 3 D Differential signal transmits data between BioCARDKey and PC 4 GND Reference voltage level for power supply NO...

Страница 9: ...255 N 4 Header Instruction Data length N Data Checksum Header Always 01H to indicate the start of a command Instruction The instruction code of the command to be carried out by the BioCARDKey Data Len...

Страница 10: ...the third byte represent data length N Data Data contents of the command For a READ command for example the data bytes would specify the start address and the number of bytes to be read For a WRITE c...

Страница 11: ...lification of the command execution status A table listing the possible values of the status bytes SW1 and SW2 and the corresponding meaning is given in Appendix B Data Length Number of subsequent dat...

Страница 12: ...a READ_DATA command for example the data bytes would contain the contents of the memory addresses read from the card The data bytes can represent values read from the card and or status information Ch...

Страница 13: ...der to the computer are not desired they can be disabled with the SET_NOTIFICATION command Please note that the setting made with this command is volatile and will be lost with the next reader reset o...

Страница 14: ...3 H 3 41H A The following example shows the transmission of a command with instruction code A2H and one data byte with the value 3DH The command has the following structure byte 1 2 3 4 5 Header Instr...

Страница 15: ...INTERNAL MAX_C MAX_R C_TYPE C_SEL C_STAT INTERNAL 10 bytes data for internal use only MAX_C The maximum number of command data bytes MAX_R The maximum number of data bytes that can be requested to be...

Страница 16: ...apt to slower host system speeds The time delay is given by N 0 1msec with N ranging from 0 255 00 FFH The default value is N 0 delay changes only valid on RS232 reader BAUD RATE Selects the baud rate...

Страница 17: ...e RESET command only for the case when no card type is selected or when the card type 00H is selected For all other cases please refer to the specific section described for each individual card type C...

Страница 18: ...Card Status Message Response data format No response data 7 1 6 SET_PPS_MODE This command selects the PPS mode to be used Command format Instruction Code Data length Data PPS_Mode 07 H 01 H NOTIFY Spe...

Страница 19: ...length 80 H 00 H Response data format ATR ATR Answer To Reset as transmitted by the card according to ISO7816 3 NOTE The ATR is only returned in the BioCARDKey response if the communication protocol o...

Страница 20: ...ata length Le 0 means no data is expected from the card NOTE With the T 0 communication protocol it is not possible to transmit data to the card and from the card in a single command response pair Hen...

Страница 21: ...protocol Command format Instruction Code Data length Data LEN T1 BLOCK FRAME A1 H LEN Length of APDU command data N DATA T1 Block frame to be sent to the card Response data format BYTE 1 BYTE N BYTE x...

Страница 22: ...the GET_ACR_STAT command correspond with the respective card types Cyber mouse Card Type Code Card Type 00H Auto select T 0 or T 1 communication protocol 0CH MCU based cards with T 0 communication pro...

Страница 23: ...60 04 Card not powered up This status code is also returned in a response if the card was temporarily removed during a card access 60 05 Invalid Instruction Code 60 20 Card failure 60 22 Short circui...

Страница 24: ...t is also recommended that before each touch the sensor be cleaned as described in section D 3 Appendix C 2 Periodic Cleaning Dampen a lint free cloth or cotton swab with alcohol or acetone Gently rub...