8.1.3.
PC_to_RDR_GetSlotStatus
Get the current status of the slot.
Offset
Field
Size
Value
Description
0
bMessageType
1
65h
1
dwLength
4
00000000h
Size of extra bytes of this message
5
bSlot
1
Identifies the slot number for this command
6
bSeq
1
Sequence number for command
7
abRFU
3
Reserved for future use
The response to this message is the
RDR_to_PC_SlotStatus
message.
8.1.4.
PC_to_RDR_XfrBlock
Transfer data block to the ICC.
Offset
Field
Size Value
Description
0
bMessageType
1
6Fh
1
dwLength
4
Size of abData field of this message
5
bSlot
1
Identifies the slot number for this command
6
bSeq
1
Sequence number for command
7
bBWI
1
Used to extend the CCIDs Block Waiting
Timeout for this current transfer. The CCID will
timeout the block after “this number multiplied
by the Block Waiting Time” has expired.
8
wLevelParameter
2
0000h
RFU (TPDU exchange level)
10
abData
Byte
array
Data block sent to the CCID. Data is sent “as
is” to the ICC (TPDU exchange level)
The response to this message is the
RDR_to_PC_DataBlock
message.