ACS-CONTROL-SYSTEM GmbH
l Lauterbachstr. 57 l D-84307 Eggenfelden l www.acs-controlsystem.de l [email protected]
16
14
5. Setting up the device
Menu level
Parameterisation level
Analog values for setpoints,
InP.01 … InP.30:
The setpoints are always set according to the selected input signal. The desired analog values
can be freely parameterised in ascending order.
Device undercut,
dI.Und:
Default:
-i9999
With this function the device undercut (
_ _ _ _ _
) can be defined on a definite value. Exception is
input type
4-20 mA
, it already shows undercut at a signal <1 mA, so a sensor failure is marked.
Display overflow,
dI.OUE:
Default:
99999
With this function the display overflow (
_ _ _ _ _
) can be defined on a definite value.
Input variable of process value,
SIG.in
:
Default:
a.meas
With this parameter, the device can be controlled via the analog input signals
a.meas
= 0-20 mA,
4-20 mA or 0-10 VDC or via the digital signals of the interface
M.bus
= RS232/RS485 (Modbus
protocol). With
[P]
the selection is confirmed and the device changes into menu level.
Back to menu group level,
rEt:
With
[P]
the selection is confirmed and the device changes into menu group level
„–INP–“
.