3
AMBIENT_OT_FAULT
Ambient temperature >60°C = 1 ; Normal =0
2
AMBIENT_OT_WARNING
Ambient temperature >55°C = 1 ; Normal = 0
[1:0]
Reserved
Return=0
Contents in 80h (STATUS_OF_3V3 And 5V) Command Code:
Bit Number
Status Bit Name
Meaning
7
5V_OC_ FAULT
5V_IOUT > Max Current of 130%@ 1Sec = 1 ;
Normal = 0
6
3V3_OC_FAULT
3V3_IOUT > Max Current of 130%@ 1Sec = 1 ;
Normal = 0
5
5V_UV_WARNING
VOUT < 4.5V = 1 ; Normal = 0
4
3V3_UV_WARNING
VOUT < 3.0V = 1 ; Normal = 0
3
5V_OV_WARNING
VOUT > 5.5V = 1 ; Normal = 0
2
5V_OC_WARNING
5V_IOUT > Max Current of 110%@ 1Sec = 1 ;
Normal = 0
1
3V3_OV_WARNING
VOUT > 3.6V = 1 ; Normal = 0
0
3V3_OC_WARNING
3V3_IOUT > Max Current of 110%@ 1Sec = 1 ;
Normal = 0
Contents in B0h (PSU_STATUS) Command Code:
Bit Number
Status Bit Name
Meaning
[7:4]
Reserved
Return=0
3
PSU2 PRESENT
Module Plug OUT = 1 ; Module Plug IN = 0
2
PSU1 PRESENT
Module Plug OUT = 1 ; Module Plug IN = 0
1
PSU2 STATUS
FAIL = 1 ; OK = 0
0
PSU1 STATUS
FAIL = 1 ; OK = 0
MFR Meaning:
Command Code
Command Name
Meaning
99h
MFR_ID
ETASIS
9Ah
MFR_MODEL
EFRP-S2287HPM
9Bh
MFR_REVSION
A0 ~ Z9
9Eh
MFR_SERIAL
Code = 12 (ex. T201XXG00001)
A7h
MFR_POUT_MAX
280 (W)
A8h
MFR_TAMBIENT_MAX
40 (°C)
Содержание ANR-C62-N1 Series
Страница 19: ...ANR C62xN1 Series 19 www acrosser com 1 Ear brackets 2 2 5 HDD with sponge ...
Страница 20: ...ANR C62xN1 Series 20 Acrosser Technology Co Ltd 3 3 5 HDD with sponge 5 7mm HDD bay with screws ...
Страница 21: ...ANR C62xN1 Series 21 www acrosser com 2 2 Slide rail Assembly 1 Slide rail Screw 2 Screw List ...
Страница 26: ...ANR C62xN1 Series 26 Acrosser Technology Co Ltd ...
Страница 28: ...ANR C62xN1 Series 28 Acrosser Technology Co Ltd Step 5 Lock all the screws back ...