Per Port Configuration

Select the port you wish to configure and you will be able to view the current settings and status 
of the port. 

Path Cost

: Enter a number between 1 and 200,000,000. This value represents the “cost” of the 

path to the other bridge from this transmitting bridge at the specified port. 

Priority

: Enter a value between 0 and 240, using multiples of 16. This is the value that decides 

which port should be blocked by priority in a LAN. 

Admin P2P

: Some of the rapid state transitions that are possible within RSTP depend upon 

whether the port of concern can only be connected to one other bridge (i.e. it is served by a 
point-to-point LAN segment), or if it can be connected to two or more bridges (i.e. it is served by 
a shared-medium LAN segment). This function allows the P2P status of the link to be 
manipulated administratively. “

True”

 means P2P is enabled, while “

False”

 means P2P is 

disabled.   

Admin Edge

: A port directly connected to the end stations cannot create a bridging loop in the 

network. To configure this port as an edge port, set the port to the 

True

 state.   

Admin Non STP

: Status shown here indicates whether this port includes the STP mathematic 

calculation. 

True

 means that this port does NOT include the STP mathematic calculation. 

False

means that this port includes the STP mathematic calculation. 

Once you finish your configuration, click 

Apply

 to save your settings. 

Note: 

Always remember to select 

Save Configuration

 to save your settings. Otherwise, your 

new settings will be lost when the switch is powered off. 

Redundant Ring 

Redundant ring technology provides a faster redundant media fail-over recovery than the 
Spanning Tree Protocol (STP), or Rapid Spanning Tree Protocol (RSTP). But unlike STP/RSTP, 
it additionally requires that all switches in the media ring be of the same brand (have the same 
redundant ring method), as most redundant ring algorithms are proprietary and rarely 
interoperable. Since STP and RSTP are standard IEEE protocols, switches that employ these 
two methods of media redundancy are generally interoperable with one another. 

With redundant ring, every switch in the ring must support the same redundant ring method and 
have two ring member ports. One switch in this ring is dedicated to serve as Ring Master, and 
one of its two member ports will be temporarily blocked--this is referred to as the backup port. 
The other member port is called the working port. The other switches in the ring are called 
working switches, and both their member ports are called working ports. When a segment of this 
ring fails, the backup port/path will automatically become a working port/path to recover the 

                    failure.

Содержание EIS-408FX-M

Страница 1: ...0Base TX and 2x 100Base FX User s Manual ACROMAG INCORPORATED Tel 248 624 1541 30765 South Wixom Road Fax 248 624 9234 P O BOX 437 Wixom MI 48393 7037 U S A Copyright 2005 Acromag Inc Printed in the U...

Страница 2: ...il Mounting Installation 2 6 Wall Mounting Installation 2 7 Chapter 3 Web based Management 3 1 Introduction 3 1 Preparation for Web Management 3 1 System Login 3 1 Configuration via the Web based Mana...

Страница 3: ...is switch is smart enough to temporarily disable the second path holding it as a backup in case the primary path fails It also includes a normally closed alarm relay to signal a port failure if enable...

Страница 4: ...Ethernet collision domain is said to terminate at the switch port That is a two port switch will effectively break a network into two distinct data links or segments An eight port switch like the Acr...

Страница 5: ...ports IEEE 802 3 10Base T 802 3u 100Base TX 100Base FX Non blocking store and forward switching architecture 1Mbits embedded buffer memory with 2K entry MAC address table Web based reconfiguration wit...

Страница 6: ...Wall Mounting Installation Introduction Panel Layout Front View 1 LED indicators PWR RM PWR1 PWR2 FAULT 2 DIP switches to enable port alarms and designate redundant Ring Master 3 RJ 45 ports w integr...

Страница 7: ...F No power 1 is being supplied Green Power 2 is ON PWR 2 OFF No power 2 is being supplied Green Indicates this switch is designated as the redundant Ring Master R M OFF Indicates switch is NOT the Rin...

Страница 8: ...res of your DC supply into the V and V contacts of the terminal block connector The acceptable wire range is 12 to 24 AWG 2 Tighten the terminal screws to prevent the wires from coming loose 3 OPTIONA...

Страница 9: ...DI MDI X crossover and automatic 10 100Mbps data rate sensing for 10Base T or 100Base TX connections Automatic MDI MDI X crossover allows you to connect to other switches hubs or workstations without...

Страница 10: ...the data can be sent If the aging time is too short the MAC address table will constantly refresh resulting in excess consumption of switch computing resources For this reason a longer aging time is r...

Страница 11: ...is positioned at the top 2 For flat surface or wall mounting you can remove the DIN Rail clip in similar fashion Follow these steps to mount the switch to the DIN rail track 1 Insert the upper end sp...

Страница 12: ...witch 2 Use a screwdriver to attach the wall mounting plate to the rear panel of the switch using the six screws provided Tighten these screws to secure the switch to the wall mounting plate 3 Use the...

Страница 13: ...ble Java applets to use network ports Preparation for Web Management Before you attempt to use the embedded web interface to manage switch operation verify that the switch is properly installed on you...

Страница 14: ...configure Rapid Spanning Tree Protocol RSTP Redundant Ring This section is to enable and configure redundant ring settings QoS This section is to enable and configure QoS Quality of Service settings...

Страница 15: ...network device in order to let the flow control of that corresponding port of the switch to work Asymmetric indicates that you don t need to activate the flow control function of the remote network de...

Страница 16: ...tings Note Remember to click on the Save Configuration button to save your settings Otherwise the settings you made will be lost when the switch is powered off Switch Settings With the Switch Settings...

Страница 17: ...l monitored ports will be copied to the mirror ports You can choose a single port or any combination of ports but you can only monitor them in one mirror mode To disable this function set the monitor...

Страница 18: ...ember to select Save Configuration to save your settings Otherwise the settings you made will be lost when the switch is powered off Because the port based VLAN is defined on the switch itself and doe...

Страница 19: ...3 7 Basic 1 Click on Add button to add a new tag based VLAN...

Страница 20: ...to communicate with one another 5 Here you can specify the egress outgoing VLAN frames to be Tagged frames or Untagged frames Click on Apply to apply your settings Tag Indicates that egress outgoing f...

Страница 21: ...o transmit data to each other this is their tagged port The tagged VLAN settings for switch 1 are as follows settings for switch 2 are the same those for switch 1 1 You must specify which port s belon...

Страница 22: ...VLAN ID VID to which it belongs Tag uplink ports do not use port VLAN ID s 4 Always remember to select Save Configuration to preserve your settings Otherwise your settings will be lost when the switch...

Страница 23: ...Mask You can assign the subnet mask for the IP address here If the DHCP Client function is enabled you don t need to assign the subnet mask Gateway You can assign the gateway for the switch here The d...

Страница 24: ...ter SWT Swedish Winter 1 hour 1 pm EET Eastern European USSR Zone 1 2 hours 2 pm BT Baghdad USSR Zone 2 3 hours 3 pm ZP4 USSR Zone 3 4 hours 4 pm Local Time Zone Conversion from UTC Time at 12 00 UTC...

Страница 25: ...a network The spanning tree was created to combat the negative effects of message loops in switched networks A spanning tree uses a spanning tree algorithm STA to automatically sense that a switch has...

Страница 26: ...40 seconds here This value represents the time that a bridge will wait without receiving Spanning Tree Protocol configuration messages before attempting a reconfiguration If this switch is not the ro...

Страница 27: ...e the STP mathematic calculation False means that this port includes the STP mathematic calculation Once you finish your configuration click Apply to save your settings Note Always remember to select...

Страница 28: ...nt ring function by checking this option Note You must enable the redundant ring function before connecting any backup path to prevent the inadvertent generation of message loops Working Ports You can...

Страница 29: ...ked and connects to the backup redundant path the upper right corner path is the backup path The settings of Switch 1 The settings of Switch 2 The settings of Switch 3 The settings of Switch 4 Note Be...

Страница 30: ...that it has two message paths to another Switch 1 is configured to be the master switch and the backup path will be decided by this master switch For our example we specified the path on the right as...

Страница 31: ...iority to the lowest priority For example the system will process 8 packets with the highest priority in the queue then 4 with middle priority then 2 with low priority and 1 with the lowest priority a...

Страница 32: ...multitude of other computers that have identified themselves as being interested in receiving the originating computers data Multicasting is useful for such applications as updating the address books...

Страница 33: ...fferent multicast groups VID and member ports and IP multicast addresses that range from 224 0 0 0 to 239 255 255 255 Once you finish your configuration click on Apply to apply your settings Security...

Страница 34: ...s of your TFTP server here Backup File Name Specify the correct backup file name here Once you finish your configuration click on Apply to apply your settings TFTP Update Firmware In this section you...

Страница 35: ...r default state including the IP address please use the reset button on the front panel of your switch refer to the Reset Button section System Reboot System Reboot allows you to reset the switch soft...

Страница 36: ...t ingress incoming traffic and egress outgoing traffic rate controls For example let s assume port 1 is at 10Mbps you can set its effective transmit egress rate to be 1Mbps and receive ingress rate to...

Страница 37: ...hernet cables are categorized into unshielded twisted pair UTP and shielded twisted pair STP types Shielded cables are recommended In general category 3 4 and 5 Ethernet cables are suitable for system...

Страница 38: ...equipment or other wiring A high number of oversized packets can result from a bad transceiver excessive cable noise or from a speed mismatch between the switch ports and the connected devices LED Ind...

Страница 39: ...EIA TIA 568 100 ohm 100m maximum length 100BaseT X Twisted pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100 meters maximum length 100BaseFX Select multi mode or single mode cables per model Power Inpu...

Отзывы: