AcroPack Series AP560
CAN Bus Interface Module
- 19 -
Location Register, (Read Only)
–
(Base + 04H)
This read-only
register is used identify the module’s plugin location
in a
system.
Table 6 Location Register
Bit(s)
FUNCTION
2:0
Module Site Location Bits. These bits identify the location on
the carrier of the AP module.
000
Carrier Site A
001
Carrier Site B
010
Carrier Site C
011
Carrier Site D
7:3
Module Slot Location Bits. These bits identify the slot location
of the AP module in a system. The Carrier may use backplane
signals as in a VPX system or a carrier DIP switch to uniquely
identify the system location of the carrier.
XXXXX System Slot identification bits are described by the
AcroPack carrier card.
31:8
Not Used
Channel Interrupt Pending Register, (Read) - (Base + 08H)
This read/write register is used to determine the pending status of
interrupts. It also reports if the CAN controller is BUSY.
The function of each of the interrupt register bits are described in Table 7. A
power-up or system reset sets all interrupt register bits to 0.
Содержание AcroPack AP560
Страница 28: ...AcroPack Series AP560 CAN Bus Interface Module 28 Figure 2 Standard Data Frame...
Страница 30: ...AcroPack Series AP560 CAN Bus Interface Module 30 Figure 3 Extended Data Frame...
Страница 32: ...AcroPack Series AP560 CAN Bus Interface Module 32 Figure 4 Remote Frame...
Страница 34: ...AcroPack Series AP560 CAN Bus Interface Module 34 Figure 5 Error Frame...