Acrolon TankNET TC-1 Скачать руководство пользователя страница 17

Attaching the TC-1 Display

CAUTION: 

· 

Hand tighten lid screws. DO NOT OVER TORQUE

· 

Fasten upper-left screw, then lower-right screw, then upper-right screw and then lower-left 
screw

· 

Ensure all conduit and inlet fittings are (water) tight

ELECTRICAL SHOCK HAZARD

BEFORE APPLYING POWER ENSURE THAT ALL WIRING AND VOLTAGES ARE 
CORRECT AND THAT THE TC-1 DISPLAY IS SECURELY FASTENED TO ITS POWER 
SUPPLY.

TC-1 for Power Line Networking

Quick Start Installation Guide

Acrolon Technologies, Inc.

Содержание TankNET TC-1

Страница 1: ...NKNET TC 1 Series II Controller Quick Start Installation Guide Version 4 1 2013 Power Line Networking Expansion I O TC 1 for Power Line Networking Quick Start Installation Guide Acrolon Technologies I...

Страница 2: ...l to draw your attention to important installation operational and safety information A NOTE marks a short message to alert you to an important detail A CAUTION safety alert appears with information t...

Страница 3: ...y DO NOT CONNECT POWER to the product IF THIS LABEL IS MISSING For label reading 120VAC 60Hz connect controller power supply input to 120VAC 50 60Hz single phase power distribution system For label re...

Страница 4: ...15VAC Input Voltage Specification CAUTION For continued protection against risk of fire replace only with same type and rating fuse F1 Little fuse 218P Series 6 3A 250V time delay 5 x 20 mm F2 F3 Wick...

Страница 5: ...Mechanical Dimensions All dimensions are inches TC 1 for Power Line Networking Quick Start Installation Guide Acrolon Technologies Inc...

Страница 6: ...d with TC 1 Bracket Screws x4 Included with TC 1 NOTE Use only supplied brackets and screws Hand tighten only Do not over torque screws DO NOT DRILL NEW HOLES OR ENLARGE EXISTING HOLES TC 1 Power Supp...

Страница 7: ...ES OR ENLARGE EXISTING HOLES Mounting Screws M4 or 8 Mounting holes Ice shield on tank supplied by other TC 1 Power Supply BASE Controller Mounting on to Ice Shield TC 1 Power Supply TC 1 for Power Li...

Страница 8: ...ool Heat Output Wiring Pump Ctrl Output Wiring TC 1 Power Supply Mounted on ice shield Ice Shield on Tank Temperature Probe Cable 4 Wire Probe Shown TC 1 Power Supply Water tight cable gland included...

Страница 9: ...in TC 1 Display Rear View TC 1 Display REAR VIEW Power Connector Shown w ribbon cable Communications Connector P1 Removable Terminal Block RELAY I O EXPANSION CARD F1 RELAY FUSE on optional Relay I O...

Страница 10: ...en extending TankNET 4 wire temperature probes Removable Probe PLUG Removable Power PLUG IMPORTANT TC 1 Series II Controllers support both 4 Wire or 2 Wire TankNET Temperature probes Please first iden...

Страница 11: ...ere 2 Wire Temperature Probe Wiring Factory Default IMPORTANT Use only shielded cabling when extending probe cables Terminate shield drain wire at controller end only see JP4 above Shield drain Wire T...

Страница 12: ...dity probe probe 2 12V 5V JMP1 4 20MA TEMP JMP2 OPTIONAL EXPANSION CARD Not applicable Temperature Humidity Wiring IMPORTANT Use only shielded cabling when extending probe cables Terminate shield drai...

Страница 13: ...ended only to PILOT an external pump start stop starter CR1 DO NOT ATTACH PUMP MOTOR DIRECTLY TO THESE CONTACTS USE ONLY 16 or 18 AWG WIRE DO NOT EXCEED 120VAC 2 AMPS I O 2 I O 1 COM1 COM 2 NO2 CR1 LI...

Страница 14: ...ended only to pilot external relays CR or solenoids USE ONLY 16 or 18 AWG WIRE DO NOT EXCEED 120VAC 2 AMPS I O 2 I O 1 COM1 COM 2 NO2 CR LINE NEUTRAL RELAY I O EXPANSION CARD CR STAGE 3 STAGE 4 STAGE...

Страница 15: ...pump control relay contacts are intended only to PILOT an external pump start stop starter b DO NOT EXCEED 120VAC 1 AMPS 3 USE ONLY 16 or 18 AWG WIRE FOR ALL CONTACTS GND AOUT1 AOUT2 RLY RLY R E D B L...

Страница 16: ...Supply Mounted on ice shield Ice Shield on Tank Securely Attach Communications Cable Securely Attach Power Cable OPTIONAL Expansion I O Wiring TC 1 Display OPTIONAL I O Expansion Card RELAY I O CARD...

Страница 17: ...ght screw and then lower left screw Ensure all conduit and inlet fittings are water tight ELECTRICAL SHOCK HAZARD BEFORE APPLYING POWER ENSURE THAT ALL WIRING AND VOLTAGES ARE CORRECT AND THAT THE TC...