![acrilan Professional Vapor X15 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/acrilan/professional-vapor-x15/professional-vapor-x15_use-and-installation-manual_2841093003.webp)
- 3 -
IMPORTANT !!
Consult the technical data sheet of the
shower booth to be installed.
For the system to operate correctly the feed
water must not contain impurities (sand,
rust, etc.) and must have a pressure ranging
from 1.5 to 3 bar.
We suggest the installation of a 100
micron feed water lter and of a water
softener.
Before positioning the shower box
,
it is the
duty of whoever assembles the product to
check that all the connections are watertight.
This guarantee is not valid if there are
leaks after the product has been installed.
SAFETY
DISTANCES
Shower areas, saunas, bathrooms, swimming
pools and the surrounding areas are classi-
ed by EN safety standards as special zones,
since the humidity and dampness associated
with these areas can make them extremely
dangerous.
The standards specify four clearly-de ned
areas:
zone 0, 1, 2 and 3.
The omnipolar switch with opening of
contacts of at least 3.5 mm must be located
outside of these zones, distant from possible
contact with water.
The limits of the various danger zones may be
modi ed by the presence of walls, protective
panels and xed insulating walls which limit
access to the tub or to the shower plate.
In this case, the area is delimited by taking a
piece of string whose length is that of the area
and winding it around the wall to the opposite
side. The path taken by the end of the string
marks the danger zone.
The zones that are external to the four danger
areas are considered to be normal.
PRECAUTIONS
The material used for the construction of the
shower booth is extremely tough and durable,
which is demonstrated by the widespread use
of this material in many industries.
However, this material may be damaged by
certain chemical substances such as acetones
and solvents in general, and stained by
alcohol-based liquids if these are not removed
immediately.
For this reason, it is advisable to protect the
tub with paper or cardboard (the packing
cartons may also be used) during installation,
in order to ensure that no abrasive substances
or paint come into contact with the surface.
It is also advisable to avoid placing tools on
the surface of the shower plate.
Before installing the bath, check it with
care.
Any damage of defects found after the
bath has been installed will not be covered
by the guarantee.
Immediately on delivery, check that the ap-
pliance is in perfect condition and that the
packaging is not damaged in any way.
When moving the hydromassage tub, always
grip the edges or the frame. Ensure that the
pipes are not damaged when moving the tub.
Never lift or move the column by its pipes
(or by the multipurpose holder).