ACR STOVES FB6WB Скачать руководство пользователя страница 7

Parts Information

1 03-09266-000 Base 

Casing

2 03-05639-000 Ashlip

03-00395-000 

Air Intake Section Cast with KO Panel

4 03-52287-000 Leg 

200mm

03-37696-000 

Cast Air Tunnel

6 03-02496-000 Rear 

Casing

03-15366-000 

Cast Blanking Plate

03-07216-000 

Blanking Plate Locking Bar

03-79288-000 

Left Cast Panel

10 

03-03198-000 

Door Lock Casing

11 

03-79291-000 

Right Cast Panel

12 

03-24488-000 

Lower Front Casing

13 03-37124-000  Air 

Deflector

14 

03-38224-000 

Internal Top Casing

15 

03-15519-000 

Bare Door Casing

16 03-69244-000  Top 

Casing

17 

03-00314-100 

Flue Collar 150mm Diameter Inside

18 03-66234-000  Grate 

Support

19 

03-66571-000 

Grate Right - Wood Only

20 

03-66572-000 

Grate Left - Wood Only

21 03-05404-000  Access 

Plate

23 

03-77580-000 

Chamotte Rear Brick

24 

03-77531-000 

Chamotte Side Brick

25 

03-77579-000 

Vermiculite Baffle Plate

26 03-77468-000  Log 

Retainer

27 

03-38016-000 

Primary Air Slide

28 

03-38017-000 

Secondary Air Slide

29 

03-31452-000 

Clamping Plate - Air Slider

30 

03-38223-000 

Air Tunnel Plates

31 02-27046-000  Door 

Handle

32 03-05243-000  Ashpan
33 

03-28162-000 

Bottom Heat Shield

34 03-26394-000  Glass
35 

03-26180-000 

Glass Retaining Bracket - Bottom

36 

03-29066-000 

Bttom Rope Bracket Door

37 

03-26101-041 

Glass Retaining Bracket - Top

38 

03-13612-000 

Air Slider Spacer

39 

03-18710-000 

Air Slider Washer

40 

03-22201-041 

Air Slider Screw M8X20

41 

03-22204-041 

Air Intake Retaining Screw M8X35

42 

03-19508-000 

Leg Retaining Screw M8X25

43 

03-16110-000 

Heat Shield Retaining Spacer

44 

03-19310-000 

Heat Shield Retaining Screw M8X12

45 

03-76320-000 

Leg Levelling Bolt M6X20

46 

03-19505-000 

Blanking Plate Stud M6X35

47 03-18701-000  M6 

Washer

48 03-19410-000  M6 

Nut

49 

03-18002-000 

Rear Heat Shield Retaining Screw M6X12

50 

03-13623-041 

Handle Catch Bushing

51 

03-13619-100 

Handle Catch Nut

52 

03-19304-000 

Handle Catch Bolt M6X16

53 

03-18601-041 

Handle Catch Plate Retaining Bolt M6X12

54 

03-18605-041 

Side Casing Bolt M6X30

55 

03-19507-000 

Top Casing Stud M8X20

56 03-22203-041  M8 

Nut

57 

03-19735-000 

Flue Collar Bolt M8X40

58 

03-19401-000 

Flue Collar Nut M8

59 

03-13644-041 

Handle Bushing Inside

60 

03-16601-000 

Handle Bushing Outside

61 

03-20360-000 

Handle Bolt M6X16

62 

03-21701-000 

Handle Bolt Retaining Grub Screw M6X6

63 

03-17806-000 

Door Hinge Retaining Pin 6X30

64 

03-58610-100 

Bottom/Top Hinge Pin 6X45

65 

03-16501-000 

Bottom Hinge Pin Washer

66 

03-19801-041 

Glass Retaining Plate Screw M5X10

67 

04-26420-000 

Fiberglass Round 8mm Seal (Door)

68 

04-23419-000 

Fiberglass Round 6mm Seal (Glass)

69 

04-26408-000 

Door Seal Round 8mm

70 

04-26422-000 

Fiberglass Flue Collar Gasket 10x3

Diagram No.

Part No.

Description

Langdale Cast Iron FB6 0316-1  15/03/2016  16:25  Page 12

Содержание FB6WB

Страница 1: ...or future reference Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L Document FB6WB 0101 Version 1 Date 15 03 16 Serial Number WOOD BURNER SMOKE EXEMPT AIRWASH SYSTEM 10 YEAR 10 YEAR WARRANTY Langdale Cast Iron FB6 0316 1 15 03 2016 16 25 Page 1 ...

Страница 2: ...ws Asbestos This appliance contains no asbestos if there is the possibility of disturbing any asbestos in the installation of this appliance then specialist advise must be sought and appropriate precautions taken Metal Parts This appliance may contain sharp metal edges take care when installing or servicing this appliance to avoid personal injury Please use appropriate personal protective equipmen...

Страница 3: ...ble materials There must be a minimum clearance of mm at each side and mm at the rear of the appliance from any combustible materials If using single wall flue pipe there must be a clearance of at least 3 times the diameter of the flue pipe e g 125mm diameter pipe 375mm minimum clearance from any combustible materials e g wooden beam Curtains and soft furnishings should be a minimum of 1m away fro...

Страница 4: ...s well ventilated during this period The appliance should not be operated in mild weather with smokeless fuel Under certain weather circumstances e g fog the chimney will not draw sufficiently and could cause asphyxiation Either await better weather conditions or burn wood only In the rare event of a malfunction due to overheating or a chimney fire the air slides should be shut down completely and...

Страница 5: ...ers and ash that the new fuel charge will ignite in a reasonable period If there are too few embers in the fire bed add suitable kindling to prevent excessive smoke Operating your stove Fuel overloading Never overload the stove it will work very well with two medium sized logs The amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Daily Maintenance Th...

Страница 6: ...t draft Check the flue is not obstructed Fire burns too quickly Too much draft Reduce the air control Excessive draft Install a draft stabiliser Smokes on initial Flue is cold Burn paper and kindling to increase lighting heat in flue Smokes while burning Insufficient draught Check the flue is not obstructed Low heat output Poor quality wood Use seasoned Hardwood this has a Higher calorific value P...

Страница 7: ...acket Top 38 03 13612 000 Air Slider Spacer 39 03 18710 000 Air Slider Washer 40 03 22201 041 Air Slider Screw M8X20 41 03 22204 041 Air Intake Retaining Screw M8X35 42 03 19508 000 Leg Retaining Screw M8X25 43 03 16110 000 Heat Shield Retaining Spacer 44 03 19310 000 Heat Shield Retaining Screw M8X12 45 03 76320 000 Leg Levelling Bolt M6X20 46 03 19505 000 Blanking Plate Stud M6X35 47 03 18701 00...

Страница 8: ...y and are under no circumstances binding 10 YEAR 10 YEAR WARRANTY With the aim of constantly improving our products all modifications considered necessary may be made without notice This manual is correct at time of printing Our appliances are guaranteed against faults and hidden defects subject to the following conditions The appliance must have been installed by a registered competent installer ...

Страница 9: ...ed Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Langdale Cast Iron FB6 0316 1 15 03 2016 16 25 Page 16 ...