Страница 1: ...ICAL MANUAL Malvern Multifuel Stove Model MV1MF To be retained by the user for future reference Serial Number Document MV1MF 0101 Version 1 Date 17 10 13 Thank you for purchasing an ACR Heat Products...
Страница 2: ...nce becoming damaged or unsafe which in turn could lead to personal injury or damage to the property and will void the warranty The appliance must not be modified in anyway unless authorized by ACR He...
Страница 3: ...m Please note that Building Regulations Document J advises that additional permanent air supply is required for appliances with an output of above 5Kw With modern properties additional air may be requ...
Страница 4: ...MV1MF Dimensions...
Страница 5: ...s for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control are...
Страница 6: ...s measurement can be reduced to 50mm a minimum clearance of 300mm is required above the appliance Clearances to combustible materials There must be a minimum clearance of 450mm at each side and 750mm...
Страница 7: ...distributing plate shall be taken to achieve it Flue Requirements The chimney must comply with current Building Regulations Provision must be made to provide access for cleaning the appliance the flue...
Страница 8: ...spigot in the top exit position If you intend to install the appliance using a rear flue connection the blanking plate should be swapped over as follows Remove the internal baffle plate Remove the rea...
Страница 9: ...THE UNDERSIDE OF THE GRATE This will overheat the grate and cause premature wear and distortion The internal vermiculite panels of the appliance should be checked regularly for soundness If any wear a...
Страница 10: ...s have been closed completely dial 999 for assistance If the appliance has overheated the appliance will need to be inspected for any damage before it can be operated again Recommended Fuels Wood hard...
Страница 11: ...nt of kindling wood to the top Place a small quantity of smokeless fuel on top Light the newspaper or firelighters using a long taper and push the door to When the fire is burning fiercely after a cou...
Страница 12: ...light Persistent fume emission is dangerous and must be investigated If fume emission persists open doors and windows to ventilate the room and let the fire dies out Have the chimney inspected for blo...
Страница 13: ...split logs Not enough primary air Open air control Insufficient draft Check the flue is not Obstructed Fire burns too Too much draft Reduce the air control Quickly Excessive draft Install a draft sta...
Страница 14: ...s as this will prohibit its expansion and could cause the glass to crack Ensure that all internal components are fitted correctly these may have shifted in transit Ensure that the appliance operates c...
Страница 15: ......
Страница 16: ......
Страница 17: ......
Страница 18: ...plate 3711 170A 14 1 right vermiculite brick 6081 736 15 1 left vermiculite brick 6081 744 16 1 back panel 4290 1199 17 1 log guard 4290 1216A 18 1 log guard rail right 7911 1212 19 1 log guard rail l...
Страница 19: ...s as this will prohibit its expansion and could cause the glass to crack Ensure that all internal components are fitted correctly these may have shifted in transit Ensure that the appliance operates c...
Страница 20: ...by a registered competent installer HETAS or inspected by local authority Building Control The appliance must be installed and operated in accordance with our instruction manual The guarantee is for a...
Страница 21: ...se Date of installation Installer s Name and address Installer s Registration Number Building Control Certificate Number if not installed by a registered competent installer Dealer Name and address Un...