ACR Electronics RCL-100 Скачать руководство пользователя страница 17

 

Y1-03-0138R 

17 

 

APPENDIX B - USER REPLACEABLE PARTS 

 

 

ACR/RCL-100D 

 

 

Figure 9

 - Searchlight User Replaceable Parts 

 

Item 

Number 

Description 

Quantity 

ACR Part 

Number 

Front Glass 

  HRMK 1300 

Front Frame 

HRMK 2101 

3A 

Window Weather Strip 

HRMK 1201 

3B 

Screw M4x18 

HRMK 1600 

3C 

Washer M408 

HRMK 9301 

Gasket of front frame 

HRMK 2200 

10 cm reflector 

HRMK 1301 

Protection Cover 

HRMK 2102 

O-Ring #594 

HRMK 2202 

8A 

55W quartz halogen bulb (12V) 

6001 

8B 

55W quartz halogen bulb (24V) 

6003 

Shoulder Washer 

A1-05-0660-24 

10 

Base Housing 

HRMK 2103 

11 

Head Housing 

HRMK 2100 

 

 

 

Содержание RCL-100

Страница 1: ...Y1 03 0138R i ...

Страница 2: ...URP 102 POINT PAD ___________________ 5 SECTION 6 URC 102 MASTER CONTROLLER __________ 10 APPENDIX A RCL 100D SPECIFICATIONS _____________ 16 APPENDIX B USER REPLACEABLE PARTS _____________ 17 APPENDIX C BULB REPLACEMENT PROCEDURE _______ 18 APPENDIX D PRODUCT COMPONENTS ______________ 19 APPENDIX E ACCESSORY COMPONENTS _____________ 20 APPENDIX F WARRANTY USEFUL LIFE POLICY NOTICES 22 PLEASE READ...

Страница 3: ... quality raw materials and quality controlled manufacturing produce a superior product The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man This assures that the products we produce can stand up to the tough marine environment With proper care and maintenance your searchlight will be in service for years to come ACR is proud to be ISO 9001 certified the...

Страница 4: ...ght body makes it attractive for recreational and commercial vessels The Searchlight is totally enclosed and is made of rugged aluminum alloy It is gasketed and finished to be resistant to the weather Mounting Make sure the area is clean and dry The Searchlight can be mounted where desired using appropriate length 3 16 diameter stainless steel fasteners Four 4 nylon shoulder washers are supplied w...

Страница 5: ...side of the mounting location Make sure there are no obstructions behind the area where the switch is to be located e g bulkheads wires plumbing or hardware Check in advance that the coax cable from the Master Controller can be routed to this location Generally the Point Pad should be mounted in a protected area Install the surface mount Point Pad by drilling 3 holes in the dashboard location usin...

Страница 6: ...r through ACR Electronics your local Radio Shack or other sources of electronic hardware Additional Point Pads up to three 3 Pads may be used with one 1 Master Controller A standard T connector or RG 59 television type splitter is used for each additional Point Pad see Figure 2 Limit the total length of all coax cable used to 300 feet The URP 102 Point Pad is backwards compatible with all RCL 100 ...

Страница 7: ...Pad URP 102 Point Pad URP 102 Point Pad URC 102 Master Controller Unit URC 102 Master Controller Unit Power Source Power Source RG 59 Coaxial Cable RG 59 Coaxial Cable RG 59 Coaxial Cable RG 59 Coaxial Cable Fuse Fuse T Conn or Splitter Single Point Pad Multiple Point Pads ...

Страница 8: ...Arrows to raise or lower the Searchlight beam To activate the XRCiZ feature press and hold the ON OFF button for greater than 5 seconds The green LED indicates XRCiZ feature is enabled To deactivate the XRCiZ feature Press and hold the ON OFF button for greater than 5 seconds The red LED indicates XRCiZ feature is disabled An LED blinking red green indicates that the XRCiZ feature is now exercisin...

Страница 9: ...Y1 03 0138R 9 Figure 4 URP 102 Point Pad Surface Mount Case Figure 5 URP 102 Point Pad Flush Mount Case ...

Страница 10: ... routed to this location Mount the Master controller with the wires and coax facing down Use an appropriate fastener for your mounting location Use a sealant in fastener holes to prevent moisture intrusion General Wiring Scheme The RCL 100 has a unique wiring scheme Special attention must be paid to the following chart The Master Controller is supplied with an in line fuse holder on the Orange pow...

Страница 11: ...attached to the end of the 15 Searchlight wire harness If you must lengthen the wire harness use heavy duty wire to minimize the voltage drop This is especially important for the YELLOW lamp power and GREEN lamp ground wires Following the wiring scheme shown in Table 1 use the supplied butt connectors to connect the Master Controller to the Searchlight Wiring to Point Pad The RG 59 Coax cable is s...

Страница 12: ...ure The XRCiZ feature routinely operates all moving parts in the Searchlight to keep the motors and drive mechanism freely running Once activated and every 30 days thereafter the XRCiZ feature wakes up and operates the Searchlight The Searchlight will rotate 360 in both directions and the parabolic reflectors will move to the full up and down positions This feature keeps the Searchlight in peak wo...

Страница 13: ...brightest searchlight performance and long bulb life Also to extend lamp life the Master Controller has a timed lamp power up feature The searchlight lamps reach full intensity within 2 seconds The URC 102 Master Controller has a searchlight motor timeout feature If a Point Pad rotation switch right or left is continuously engaged for more than 50 seconds the Master Controller will interrupt the o...

Страница 14: ...Point Pads 75 ohm TV Coaxial Cable 75 ohm TV Coaxial Cable T Connector or Optional 75 Ohm Splitter for Multiple RCL 100 Point Pads Ground Blue Orange Note Wiring must be in accordance with this diagram Improper wiring will damage components 12 VDC or 24 VDC Master Controller in line 15 amp fuse Power Source Fuse Figure 7 URC 102 Master Controller Wiring Diagram ...

Страница 15: ...Y1 03 0138R 15 Figure 8 URC 102 Master Controller ...

Страница 16: ...55WDX 70W halogen Lamp X2 base G6 35 JDC24V 55WDX Peak beam candle power candela 200 000 160 000 Beam spread degrees Horizontal 7 Vertical 5 Horizontal 7 Vertical 5 Elevation angle degrees Up 9 Down 17 Up 9 Down 17 Turning angle degrees 360 360 Elevation speed 4 per second 6 per second Turning speed Fast 28 per second Slow 15 per second Fast 28 per second Slow 15 per second Weight 7 15lbs 3 24 kg ...

Страница 17: ...ame 1 HRMK 2101 3A Window Weather Strip 1 HRMK 1201 3B Screw M4x18 2 HRMK 1600 3C Washer M408 2 HRMK 9301 4 Gasket of front frame 1 HRMK 2200 5 10 cm reflector 2 HRMK 1301 6 Protection Cover 1 HRMK 2102 7 O Ring 594 1 HRMK 2202 8A 55W quartz halogen bulb 12V 2 6001 8B 55W quartz halogen bulb 24V 2 6003 9 Shoulder Washer 4 A1 05 0660 24 10 Base Housing 1 HRMK 2103 11 Head Housing 1 HRMK 2100 ...

Страница 18: ...lbs to cool 2 Remove two screws holding the front flange and glass in place 3 To remove the old lamp bulbs grasp base of the lamp and pull straight out WARNING Do not touch glass parabolic reflector with fingers or tools 4 Install the new lamp bulb using a soft clean cloth to avoid touching the bulb with your fingers Insert the lamp bulb pins into socket and press firmly in place CAUTION If the la...

Страница 19: ... 0776 Washers 2 A1 05 0777 Warranty Card 1 A1 20 1019 Product Support Manual 1 Y1 03 0138 Mounting Templates 1 Y1 03 0138 1 Product No 1931 3 RCL 100D 24 V Searchlight Installation Kit includes Description Quantity ACR Part Number Searchlight RCL 100D 24 V 1 A3 06 1106 4 Kit Nylon Washers 4 1 A3 06 1940 Connector F 2 A1 03 0220 Cable Coaxial 15ft A2 07 0002 6 Master Controller URC 102 1 A3 06 2231...

Страница 20: ...R Part Number Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A1 25 0140 2 U Clamp 2 A1 17 1366 Nuts Nylon lock 2 A1 05 0776 Washers 2 A1 05 0777 Adapter Plate Flush mount 1 A1 18 1871 Adapter Plate Surface mount 1 A1 18 1892 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Pro...

Страница 21: ... 4 A1 03 0220 Instruction Sheet Point Pad 1 Y1 06 0179 Mounting Templates 1 Y1 03 0138 1 Product No 9283 3 Remote Control Installation Kit Includes Description Quantity ACR Part Number Master Controller URC 102 1 A3 06 2231 Connector In Line 8 A1 03 0222 Point Pad URP 102 with Surface Mount Case 1 A3 06 2230 Case Flush Mount 1 A1 18 1875 2 Gasket Surface Mount 1 A1 25 0140 1 Gasket Flush Mount 1 A...

Страница 22: ...ars for the following products EPIRB PLB S VDR SSAS Useful Life Policy The typical service life of a properly maintained Product is limited to 12 years from date of manufacture Products that are 12 years and 1 month or older from date of manufacture will not be serviced by ACR or our Battery Replacement Centers A Product that is 12 or less years old from date of manufacture will be serviced as lon...

Страница 23: ...ty IEC 61000 4 2 1995 Electrostatic Discharge IEC 61000 4 3 1995 Radiated Immunity IEC 61000 4 4 1995 Immunity to Fast Transients IEC 61000 4 6 1995 Conducted Immunity Power and I O Leads IEC 61000 4 11 1994 Voltage Dips and Interrupts Manufacturer ACR Electronics Inc European ACR Electronics Inc 5757 Ravenswood Road Representative European Office Fort Lauderdale FL 33312 1 Rose Cottages Pitmore L...

Отзывы: