background image

Y1-03-0233 Rev. F 

22 

Always  refer  battery  replacement  and  any  other  beacon  service  to  a 
factory  authorized  Service  Center.  Find  a  Center  near  you  at 

http://www.acrelectronics.com/brc.htm

.  Battery  replacement  includes 

servicing  the  beacon  by  replacing  all  o-rings,  testing  the  water  seal  and 
the electrical properties and doing a full functional test on the unit. 
 

NOTE:

  There  are  no  user  serviceable  items  inside  the  beacon.  Do  not 

open  the  beacon  except  to  disable  (in  case  of  faulty  or  accidental 
activation). Otherwise, always have the beacon serviced. 
 

 

WARNING: Battery contains lithium 

To  avoid  possible  fire,  explosion,  leakage  or  burn  hazard,  do  not  open, 
recharge,  disassemble  or  heat  beacon  above  +70ºC  (+158ºF)  or 
incinerate. 
 
These  products  contain  lithium  in  the  battery.  Various  beacons  may  or 
may  not require special shipping instructions due to the lithium batteries 
and  changes  in  shipping  regulations.

 

Shipping  of  hazardous  materials 

requires  special  handling  and  documentation.  MSDS  sheets,  along  with 
shipping 

information, 

can 

be 

found 

on 

our 

website 

at 

http://www.acrelectronics.com/hazmat/default.htm

 
In the  case  of  the  RLB-36,  the  product  contains  small  batteries  that  are 
non-hazardous.  However,  regulations  can  change.  Be  advised  that  it  is 
best to verify the shipping requirements at the time you are preparing to 
ship the unit.  

4. 

Shore based maintenance for SOLAS vessels, (SBM) IMO 

MSC/Circ. 1039 

The Maritime Safety Committee has approved guidelines for shore-based 
maintenance  of  satellite  beacons,  for  the  purpose  of  establishing 
standardized  procedures  and  minimum  levels  of  service  for  the  testing 
and maintenance of satellite beacons. The first shore based maintenance 
on  all  ACR  EPIRBs  is  due  at  the  date  of  the  first  battery  replacement. 
Visit  ACR’s  website  at 

www.acrelectronics.com

  for  organizations  that 

perform shore based maintenance. 

5. 

Annual testing for SOLAS vessels, IMO MSC/Circ. 1040 

SOLAS  regulation  IV/15.9  dictates  annual  testing  of  406  MHz  satellite 
EPIRBs.  Testing  should  be  carried  out  using  suitable  test  equipment 
capable of performing the relevant measurements. All checks of electrical 
parameters should be performed in the self-test mode, if possible. These 
tests  can  be  performed  by  certified  ACR  Battery  Replacement  Centers 
(BRCs). 

Visit  ACR’s  website  at 

www.acrelectronics.com

  for  authorized 

ACR BRCs. 

 

 

Содержание GlobalFix iPRO RLB-36

Страница 1: ...PRODUCT SUPPORT MANUAL GLOBALFIX iPRO 406 MHz GPS EPIRB Model No RLB 36 Product No 2846 0 2848 0 Y1 03 0233 Rev F...

Страница 2: ...ly Asked Questions FAQs section for further information or call our Technical Service Department The website address is www acrelectronics com If in the future you lose this manual you may access and...

Страница 3: ...ACE SPECIAL ICONS______________________________ 29 APPENDIX C USER INTERFACE DIGITAL DISPLAY DURING OPERATION___________ 30 APPENDIX D USER INTERFACE DIGITAL DISPLAY DURING SELF TEST ____________ 33 A...

Страница 4: ...able to determine which country s database will have your registration information SAR forces will have information as to who you are as the owner of the beacon the name and type of vessel that you ha...

Страница 5: ...o register is online at www beaconregistration noaa gov 2 Faxing a registration is also acceptable Fax the registration form to the fax number on the top of the registration form NOTE Do not confuse t...

Страница 6: ...ww 406registration com To verify that the unit is properly programmed for your country view the UIN label on the back of the unit In the event that the beacon is not programmed for your country the sa...

Страница 7: ...s message is sent to Cospas Sarsat satellites and in turn the distress message is relayed to SAR The distress message contains important information about the beacon and its owner Additional informati...

Страница 8: ...re Activation switch with Witness Tab The activation switch embodies a special patented method of activating a beacon Refer to a subsequent section of this manual for how to activate the beacon Extern...

Страница 9: ...3 Rev F 8 GPS Interface Internal GPS Receiver Activation Test Switch Red LED Digital Display Screen OFF READY Position TEST Position ON TRANSMITTING Position Top View Switch Positions Strobes Antenna...

Страница 10: ...Release Unit HRU GPS Interface Cable Front cover hook detent Release Latch Antenna hook Water Sensor Deactivation Magnet Category 2 LowPro 3 Bracket Category 1 SeaShelter 3 Bracket Front Cover Release...

Страница 11: ...has not been successfully downloaded into the beacon the digital display will give you tips like GIVE CLEAR VIEW TO SKY In Self Test the display illustrates the test result of each step with indicati...

Страница 12: ...ls or floated in water and attached to a raft or life vest with the lanyard provided Category II beacons are designed to be manually deployed from the bracket Two conditions must be met for a Category...

Страница 13: ...longer in its bracket and when continuity is created by water between two of the top cap screws an activation circuit is completed NOTE Transmission of the 121 5 MHz and 406 MHz signals will not occur...

Страница 14: ...gory I or II beacon MANUALLY activates with the following sequence 1 Remove the beacon from its bracket 2 Activation method one Place beacon in water 3 Activation method two Lift the switch to a verti...

Страница 15: ...sion either by floating it resting it or holding it in this position Manually activate the beacon if it has not been automatically activated 5 Turning off the beacon If your beacon was manually activa...

Страница 16: ...it must be reported to the nearest search and rescue authorities The information that should be reported includes The EPIRB 15 digit Unique Identifier Number UIN Time and date Duration and cause of a...

Страница 17: ...e calendar as seen below 2 Mounting location The selection of a mounting location will vary from vessel to vessel Beacons should be protected from outside influences while being readily accessible at...

Страница 18: ...Avoid mounting locations that subject the bracket to breaking waves Avoid mounting locations that do not provide protection from harmful UV rays of the sun The bracket must be mounted facing inboard t...

Страница 19: ...at the bottom of the base The lid is tethered to the base to help prevent loss Pull the beacon with steady pressure from the bracket It is not necessary to remove the HydroFix Hydrostatic Release Uni...

Страница 20: ...ur pre drilled screw holes to use for securing the bracket to a flat surface Remove the beacon from the bracket To do this while holding the assembly lift the latch to release bracket pressure from th...

Страница 21: ...n it that must be aligned with the two notches on the Category II beacon bezel The connector is then gently inserted downward into place and turned 90 to lock the connector into the bezel If the exter...

Страница 22: ...be inspected for deterioration and or residue buildup that may affect the function of the beacon or automatic release Part of the visual check includes checking the antenna for tightness Clean the be...

Страница 23: ...electronics com hazmat default htm In the case of the RLB 36 the product contains small batteries that are non hazardous However regulations can change Be advised that it is best to verify the shippin...

Страница 24: ...lost or stolen Contact NOAA at 888 212 7283 212 SAVE or your national authority with the following information o Police department name o Police department phone number o Police case number If your E...

Страница 25: ...bracket to malfunction Check the date of manufacture on the new HRU Follow the instructions that accompany the HydroFix for marking the next expiry date and for selecting the correct rod adapter for t...

Страница 26: ...o not exceed sixty 60 Self Test cycles limit in the five year life of the battery to conserve the battery for emergency use The functional Self Test is initiated by momentarily lifting the Activation...

Страница 27: ...beacon owner wishes to verify internal GPS engine viability An extended GPS test may be invoked by holding the switch in test position for 10 seconds after Self Test completes The display will show th...

Страница 28: ...lead to a faster rescue Since the last valid GPS position data may stay in the memory for up to 4 hours the user should take care to make sure that the GPS position data stored is accurate This can b...

Страница 29: ...s Sarsat emergency system When the beacon is turned on the internal GPS is immediately turned on and it attempts to acquire positional coordinates GPS coordinates can be acquired any time that the GPS...

Страница 30: ...the ACR website at www acrelectronics com APPENDIX B USER INTERFACE SPECIAL ICONS Characters displayed during beacon operation include the following The battery gauge appears on certain screens to ind...

Страница 31: ...performance i e greatest likelihood of acquiring coordinates position the beacon so that it has a clear view of the sky The system reminds you that for optimum transmission of the emergency message al...

Страница 32: ...n available Updated GPS coordinates are sent every twenty minutes The system reports recently acquired GPS coordinates You may be able to communicate the coordinates to SAR or other persons assisting...

Страница 33: ...dinates have been sent If accompanied by a red LED flash the GPS coordinates have not been sent NOTE If GPS coordinates were not sent the system will continue to attempt to acquire the data and add it...

Страница 34: ...battery life is greater than 48 hours at 20 C the test passes The first test checks the available hours of battery life battery witness seal If remaining battery life is less than 48 hours at 20 C the...

Страница 35: ...test passes The sixth test checks four LEDs collectively the LED strobe for functionality If all LEDs are not working the test fails If all six tests pass the system advises you that Self Test passed...

Страница 36: ...t failed The system advises you to seek service from an authorized Service Center Not only should the beacon be fixed immediately it also should not be placed into service until the problem is address...

Страница 37: ...y 100 seconds while the GPS is acquiring data The system informs you that the beacon has passed the extended GPS test This message appears if the extended GPS test has passed The display indicates tha...

Страница 38: ...DEJA RDBLZ ON HASTA RESCA EPIRB AN BIS HILFE LASCI EPIRB ON KEEP EPIRB UP RIGHT TENIR RLS VERT TEN LA RDBLZ RECTA EPIRB AUFR HALT TENGA DRITO BATT 48HR BATT 48HR BAT 48 HR BATT 48H BATT 48HR MEM MEM...

Страница 39: ...oordination Center RCC The RCC dispatches Search and Rescue SAR forces The addition of the GEOSAR satellite system greatly improves the reaction time for a SAR event This satellite system has no Doppl...

Страница 40: ...to 131 F Class 2 30 C to 70 C 22 F to 158 F Class 2 406 MHz TRANSMITTER Frequency 406 037 MHz Power output 5 W Digital message format Standard location protocol for the USA Beacon can be reprogrammed...

Страница 41: ...KIND EXPRESS OR IMPLIED AS TO MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER MATTER WITH RESPECT TO THIS PRODUCT The Company shall not be liable for consequential or special damages To...

Страница 42: ...EC Type Examination Module B Certificate No BSH 4612 5060959 08 EC Quality System Module D Certificate No BSH 4613 05102 1251 09 Regulations and IMO Resolution A 662 16 ITU R M 633 2 05 00 Standards I...

Страница 43: ...ed and tested annually in accordance with ServiceInterval MSC Circ 1040 Shore based maintenance of all satellite EPIRBs should be carried out at intervals not exceeding 5 years It is recommended that...

Отзывы: