ACR Electronics GlobalFix 406 Скачать руководство пользователя страница 11

14

Y1-03-0157  Rev. T1

3.2

AUTOMATIC DEPLOYMENT & DEACTIVATION

(Product No. 2742 

only

)

3.2.1

Automatic deployment and activation occurs when the vessel
sinks and a hydrostatic release device frees the beacon from the
bracket allowing it to float to the surface. Built-in sensors detect
that the beacon is no longer in its bracket and is in water. This
condition will automatically activate the beacon.

Note:  Transmissions of the 121.5 MHz and 406 MHz signal
will not occur until 50 seconds after activation.

3.3

MANUAL DEPLOYMENT & ACTIVATION

3.3.1

The 

GlobalFix™ 406

 

 can be manually deployed by removing

the retaining pin, removing the cover, then removing the beacon
from the bracket. Once removed, the beacon can be activated by
being placed in water or by lifting the thumb switch towards the
antenna and placing the thumb switch back down on the oppo-
site side of the EPIRB.  Activating the beacon in this manner
breaks off the Activation Indicator Plastic Pin and exposes the
"ON" symbol 

 " 

z

 "

 on the thumb switch indicating that the

beacon is turned "ON".

Note:  Some countries fine vessel owners for causing false
alarms. The permanent breakage of the Activation Indicator
Plastic Pin is a positive indication of a manual activation.

3.4

MANUAL ACTIVATION WITHOUT DEPLOYMENT

3.4.1

The 

GlobalFix™ 406 

can be activated while still in its bracket

by placing the thumb switch in the ON position. Activation by
this method overrides all sensors and turns the beacon “ON”.

The caution note above still applies.

3.5

DEACTIVATION

3.5.1

The 

GlobalFix™ 406

 can be deactivated by:

If manually activated:

11

Y1-03-0157  Rev. T1

SECTION 2 - INSTALLATION

  (Attach antenna tightly onto unit)

2.1

MOUNTING LOCATION 

(Product No 2742)

2.1.1

The 

GlobalFix™ 406

 float-off mounting bracket should be

mounted securely to a 

vertical or horizontal surface

 (the mount

has predrilled holes for attachment to a flat surface) where there
are no overhead obstructions. Location aboard a vessel must be
chosen to allow the EPIRB to float free of sinking craft and as
high as possible especially on small vessels. This will help
ensure operation of the hydrostatic release unit in the event the
vessel capsizes without sinking.

2.1.2

The location selected must be sufficiently rigid to support the
weight of the total installation and at the same time consider
vibration, exposure to the elements, exposure to surrounding
hazards such as equipment movement, doors being opened,
accidental covering, personnel traffic, etc., and yet be readily
accessible at all times for the emergency use for which the
beacon is intended.

2.1.3

Also to be considered in selecting a location for installation is
the harmful effect that certain corrosive vapors might have on
the beacon. Under no circumstances should a location be se-
lected for installation where the beacon would be jeopardized
by any foreign articles being temporarily or permanently posi-
tioned during “at sea” or “in port” activities.

CAUTION:

                      Care must be taken to prevent any lanyard, line, or
other emergency equipment that may be attached to the beacon
from becoming entangled or fouled which could prevent the
beacon from being removed in an emergency.

2.1.4

The 

GlobalFix™ 406

 float-off mounting bracket should be

securely attached to the vessel. The use of #10 stainless steel
hardware is recommended.

2.1.5

Do not mount the 

GlobalFix™ 406

 in the vicinity (2 meters) of

strong magnetic (such as loud speakers) or electric (such as
radar or high power radio transmitter) fields.

Содержание GlobalFix 406

Страница 1: ...ency Position Indicating Radio Beacon FCC Type Accepted Product No 2742 Cat I Product No 2744 Cat II Owner Vessel Radio CallSign ACR Electronics Inc 5757 Ravenswood Road Fort Lauderdale Fl 33312 1 954...

Страница 2: ...r is transferring the beacon to a new owner the current owner is required to inform the national authority by letter facsimile or telephone of the name and address of the new owner The subsequent owne...

Страница 3: ...Administration or other national authority It is the user s responsibility to fill out and mail the enclosed registration form to the appropriate agency of the country under which the vessel is regist...

Страница 4: ...the strobe indicating a successful test During self test an actual satellite message is transmitted while certain key performance parameters are measured and recorded The self test message is modifie...

Страница 5: ...x 406 transmits an encoded phase modulated radio signal to the satellite portion of the COSPAS SARSAT System The system was developed and implemented by the COSPAS SARSAT Partners Russian Federation C...

Страница 6: ...mation is immediately forwarded to an appropriate maritime Rescue Coordination Center RCC The RCC dispatches Search and Rescue SAR forces 1 3 5 The COSPAS SARSAT System includes 36 LEOSAR LUT stations...

Страница 7: ...false alarm it must be reported to the nearest search and rescue authorities The information that should be reported includes the satellite EPIRB Unique Identifier Number UIN date time duration and c...

Страница 8: ...opening on the spring and mounting bracket Insert the new hydrostatic release assembly in place by engaging it to the opening of the ejection spring and case When servicing the HRU ACR strongly recomm...

Страница 9: ...NTENANCE Check antenna for tightness 4 1 At least every ninety days the float free mounting bracket and GlobalFix 406 EPIRB should be inspected for deterioration and or buildup that may affect the fun...

Страница 10: ...continues to operate after it has been deactivated remove the four screws holding the unit together and unplug the battery to disable the unit Return it to a service center for repair 3 6 TEST 3 6 1...

Страница 11: ...nna tightly onto unit 2 1 MOUNTING LOCATION Product No 2742 2 1 1 The GlobalFix 406 float off mounting bracket should be mounted securely to a vertical or horizontal surface the mount has predrilled h...

Страница 12: ...1 The GlobalFix 406 Beacon Model 2742 is designed to be automatically deployed and activated The GlobalFix 406 may also be hand held on the deck of vessels or floated in water and attached to a raft...

Отзывы: