ACR Electronics 2726A Скачать руководство пользователя страница 8

Y1-03-0079-1 Rev. B 

 

5.0 

INSTALLATION AND MAINTENANCE

 

 
5.1 INSTALLATION 

 

 

The Survival Radio and its protective cover shall be packed with the ship’s survival craft 
or in a survival suit. When not packed with a life raft, the radiotelephone should be stored 
in an accessible place, as close to the survival craft as possible. 

 
5.2 MANDATORY 

TESTING 

 
5.2.1 Radiotelephones 

operated within the U.S.A. must be operationally tested on a periodic 

basis (FCC regulations, Part 80, section 80.834, until superseded by section 80.1095). To 
test the radiotelephone, follow the steps given below (Note: this test requires that a 
separate VHF marine radio transceiver be used to monitor transmitted and received 
signals). Any transmissions effected for the purpose of testing the Survival Radio shall be 
as brief as possible. The recommended test message format is as follows: “<name of 
station receiving the test message> THIS IS <name of station transmitting this 
text><station callsign or call letters>”. EXAMPLE: “BLUE DUCK THIS IS MARY 
JANE WXT599”.  When a second radiotelephone or the ship's receiver is utilized to 
monitor proper operation of the Survival Radio, the test distance between devices should 
be kept to a maximum and the following message format should be observed: “<name of 
station transmitting this text> THIS IS <name of station transmitting this text> 
MOBILE 1”. EXAMPLE: “MARY JANE THIS IS MARY JANE MOBILE 1 WXT599” 
(NOTE: if the unit to be tested is not on board the vessel containing the fixed station, 
“UNIT 1” should be used rather than “MOBILE 1”). 

 

a.  Remove the radio from its survival craft package. 

 

b.  Remove control panel protective cover. 

 

c.  Press and hold ON/OFF button for one (1) second. 

 

d.  Listen for the tone and for the squelch action 3 seconds after activating the unit. 

 

e.  The receiver tunes to Channel 16 automatically when unit is turned ON. 

 

f.  Listen for any activity on the frequency (channel 16). 

 

g.  If no activity is detected, transmit the test message and have someone monitor the 

transmission (see above for suggested test message formats). 

 

h.  If the test signal was not heard (full quieting), replace the battery and retest. If the 

test signal is still not heard (full quieting), have the unit inspected at your nearest 
authorized service center. 

 

i.  Have someone return the call from the monitoring station (lowest power setting) to 

verify proper radiotelephone receiver operation. 

 

Содержание 2726A

Страница 1: ...1 Rev B SR 102 Product No 2726A GMDSS 16 6 Survival Radio ACR Electronics Inc 5757 Ravenswood Road Fort Lauderdale Fl 33312 1 954 981 3333 Fax 1 954 983 5087 www acrelectronics com Email Info acrelect...

Страница 2: ...rs 4 4 0 OPERATION 5 4 1 Channel 16 Operation 5 4 2 Channel 6 Operation 5 4 3 Battery Save Feature 5 5 0 INSTALLATION AND MAINTENANCE 6 8 5 1 Installation 6 5 2 Mandatory Testing 6 7 5 3 Visual Inspec...

Страница 3: ...Y1 03 0079 1 Rev B 1 FIGURE 1 ACR GMDSS 16 6 SURVIVAL RADIO...

Страница 4: ...IVER Sensitivity 12dB SINAD 1 0mV Audio Output 300 mW BATTERY Type Primary Lithium Storage Life 10 Years Operating Life under typical 8 hours 20 C duty cycle of 1 9 i e 6 sec Tx 6 sec Rx 48 sec stand...

Страница 5: ...l rechargeable MaxCap battery pack is also available 2 3 AUTHORIZATION 2 3 1 This radio is FCC Type Accepted and GMDSS listed FCC Part 80 1101 as a survival craft two way VHF radiotelephone apparatus...

Страница 6: ...ly CHAN 16 Selects operation on Marine Channel 16 Distress Calling CHAN 6 Selects operation on Marine Channel 6 Communications USCG 3 2 OPERATING INDICATORS CHAN 16 The push switch includes a RED ligh...

Страница 7: ...turn unit off 4 2 CHANNEL 6 OPERATION CHAN 6 a Remove control panel protective cover b Strap the unit around operator s wrist hand or glove c Press ON OFF button for one 1 second to turn on the Survi...

Страница 8: ...lized to monitor proper operation of the Survival Radio the test distance between devices should be kept to a maximum and the following message format should be observed name of station transmitting t...

Страница 9: ...the test signal was not heard full quieting have the unit inspected at your nearest authorized service center p Have someone return the call from the monitoring station lowest power setting to verify...

Страница 10: ...Y1 03 0079 1 Rev B 8 FIGURE 3 CONTROL PANEL PROTECTIVE COVER...

Страница 11: ...Y1 03 0079 1 Rev B 9 6 0 BATTERY INFORMATION FIGURE 4 BATTERY REPLACEMENT...

Страница 12: ...CR Product No 1067 and a MaxCap Charger ACR Product No 2711 are also available The rechargeable battery pack will operate the unit for approximately four to six hours The charger is capable of chargin...

Страница 13: ...distress call use the two pronunciations above when calling for example also see example for part c M AIDER MAYDAY M AIDER THIS IS MARY JANE WXT599 WXT599 WXT599 c Always use the ICAO Convention Conve...

Страница 14: ...nge if it is mounted high Airborne receivers greatly extend the above range over 150 kilometers 100 miles for aircraft flying over 1500 meters 5000 ft Because of the above fact and to maximize the ran...

Отзывы: