background image

INSTALLATION INSTRUCTIONS

Preliminary Notes Before Installation

This appliance is a high efficiency, flueless, flame effect gas fire.  It provides
radiant and convected warmth both efficiently and safely utilising the latest
type catalytic convertor burner technology.

The appliance incorporates a combustion monitoring system (Oxygen
Depletion System). It must not be adjusted or put out of operation. If
replaced then manufacturers original parts must be used. (see User
Instructions).

The appliance is designed to fit various types of situations as listed in the
Installation Requirements.  

This appliance must be installed in accordance with the rules in force and only
used in a sufficiently ventilated space.  A minimum of 100cm

(15.5in

2

) pur-

pose provided ventilation is required for this appliance. An openable window
or louvre is also required. This appliance is factory set for operation on the
gas type, and at the pressure stated on the appliance data plate.

The minimum room size should be as stated in section 3.1 of these instruc-
tions to allow adequate circulation of air and ensure the correct operation of
the fire. This volume may include adjacent spaces but these spaces must not
be separated by a door. In order to convert from cubic feet (ft

3

) to cubic

metres (m

3

) divide the room volume (in ft

3

) by 35.3. This appliance is intend-

ed as a secondary source of heat only and should not be used in a room with-
out some form of background heating present.

The appliance must not be installed in a bedroom, bathroom or any sleeping
area.  The appliance does not require a flue system of any type as the cat-
alytic converter cleans the products of combustion to provide a complete
combustion system, which is intrinsically safe.

The appliance must be installed by a competent person in accordance with
Gas Safety (Installation and Use) Regulations 1998 or rules in force. It is
strongly recommended that a CORGI registered engineer is used for this pur-
pose, as they are the only persons approved by the HSE under the above reg-
ulations.

On initial light up of a new appliance, the ‘newness’ will burn off within the
first few hours of operation. During this period some smoke may be emitted
from outlet grille, this should be no cause for concern. Accordingly, the room
should be well ventilated with all windows and doors open during this period.

Read all these instructions before commencing installation.

Содержание X-Fire 1000 Granite

Страница 1: ...estone model LPG XF 1000G LPG 1000 Granite model LPG XF 1000M LPG 1000 Mirror model LPG X FIRE Widescreen Product Codes XF WSL Widescreen Limestone model XF WSG Widescreen Granite model XF WSM Widescreen Mirror model XF WSL LPG Widescreen Limestone model LPG XF WSG LPG Widescreen Granite model LPG XF WSM LPG Widescreen Mirror model LPG Acquisitions of London 24 26 Holmes Road London NW5 3AB UK Tel...

Страница 2: ...ct operation of the fire This volume may include adjacent spaces but these spaces must not be separated by a door In order to convert from cubic feet ft3 to cubic metres m3 divide the room volume in ft3 by 35 3 This appliance is intend ed as a secondary source of heat only and should not be used in a room with out some form of background heating present The appliance must not be installed in a bed...

Страница 3: ...moke etc exist may cause the walls to become discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room This appliance must be installed in accordance with the rules in force and ...

Страница 4: ... This Appliance may be installed in any room in a home except bedrooms and bathrooms Installation in living rooms is common however other rooms such as kitchens dining rooms and hall ways are permitted providing a suitable natural gas supply is available and rooms sizing and venti lation requirements are strictly adhered to see section 4 1 The appliance is designed to be versatile and as such will...

Страница 5: ...liance is 800mm 31 5in measured from the top of the appliance glass panel Combustible materials should not be positioned directly in front of the appliance within a distance of one metre Under no circumstances should any electrical equipment e g plasma screen LCD TV sets etc be posi tioned on the wall above the appliance The appliance is designed to be wall mounted alone and not in conjunction wit...

Страница 6: ... at either end of the firebox or the one in the bottom of the firebox A concealed gas connection may be made using the knock out hole in the centre back of the firebox Widescreens have entry provision avoiding the need for knock out Select the most appropriate entry point and knock out the relevant holes in both the firebox and the outer cas ing No more than 1 5m of 8mm diameter pipe must be used ...

Страница 7: ...or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product These should be constructed from metal and not plastic Insert the screws into two of the upper holes leaving 5mm protruding from the wall Temporarily hang the outer casing on the wall and mark any additional fixing points as required If the appliance is to be fitted to a...

Страница 8: ...fire OFF keep the knob pressed in return to the off position and release SPARK FAILURE The gap between the spark electrode and the pilot should be 3 5mm to produce a good spark There should be no need to adjust this If under any circumstances the piezo electric spark fails the pilot cannot be lit manually In the event of a failure to spark check the HT lead connections SETTING PRESSURE The pressur...

Страница 9: ...ng and that extra ventilation may be needed during this time Recommend that a guard be used for the protection of the young pets the elderly and the infirm SERVICING Isolate the fire from the gas supply Ensure that the fire is fully cold before attempting service A sug gested procedure for servicing is detailed below 7 8 4 9 0 10 0 1 Lay out the dustsheet and tools 2 Remove the facia section Remov...

Страница 10: ...on can be removed from the base of the pilot unit using two spanners to make cleaning easier Do not damage or try to dismantle the pilot injector The unit is factory set and the only check necessary is to ensure the spark gap is correct See speci fications for gas setting NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT If the pilot will not stay lit there is a problem with dirt...

Страница 11: ... catalyst and its seal and dis card Refit a new catalyst and seals in reverse order ensure the catalyst and door have good seals TESTING FOR FIREBOX LEAKAGE Appliances that are several years old or have been extensively dismantled should be checked for soundness It is important that all the products of combustion pass through the catalytic converters at the top of the firebox before leaving the ap...

Страница 12: ... under tray realign HT lead Fire runs for a time Loose or faulty thermocouple rectify and then cuts off Blocked pilot clean out Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there is a problem with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODI...

Страница 13: ...perature surrounds etc may discolour if fitted too close to the fire See relevant section for further details on clearances to combustibles No combustible materials or floor ing should protrude onto the hearth if fitted This appliance incorporates a combustion monitoring system ODS DO NOT burn any foreign material on this fire Under no circumstances shall the appliance be used if the glass front d...

Страница 14: ...s flock blown vinyl and embossed paper which are sensitive to even small amounts of heat should be avoided as scorching and or discolouration may occur over time The appliance may be positioned as close to a solid floor i e stone wooden laminate etc as the par ticular design of fireframe permits however it is not permitted to install the appliance within 100mm of carpet rugs or fabric materials of...

Страница 15: ...ter the spark keep the knob depressed for approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning anti clockwise to the high position The main burner should light after a few seconds To decrease...

Страница 16: ...h great care as the mirrored material can be scratched Use only a damp microfibre cloth to clean and another microfibre cloth to dry DO NOT use dirty cloths or abrasive cleaners as this may scratch the surface beyond repair SERVICING The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot The frequency of service will depend...

Отзывы: