INSTALLATION INSTRUCTIONS
Connect the discharge pipe to the other end of the flexible connector and
tighten the clamp with a screwdriver.
5.
NOTICE:
A rigid discharge pipe is recommended to prevent the pump (A)
from moving. If a flexible discharge hose is used, the pump (A) must be
secured in a manner that prevents it from moving. If it is allowed to move,
the float switch could be restricted by the sump wall, preventing the pump
(A) from turning on or off.
WARNING:
The tether length (distance between the float switch and clamp, see picture above) is
factory pre-set to 4 in. PLEASE DO NOT ADJUST IT in order to avoid pump failure.
Plug the pump (A) into a GFCI outlet. The pump is now ready for use.
6.
Check the pump (A) by filling the sump pit with water and observe the
pump's (A) operation through one complete cycle and make sure the
pump (A) cannot move in the sump pit and that the float switch moves freely
up and down.
7.
NOTICE:
After the installation of the necessary plumbing, check valve and
flexible connector, follow the glue manufacturer's instructions for safety
precautions and curing time.