DC Inverter
X-
Series for R410A Unitary Split Air Conditioner
30
Problem
Time of occurrence
Cause
The air conditioner
generates some smell.
During operation.
The room smell or the
smell of cigarette comes
out through the units.
Check the above items and adopt the corresponding corrective measures. If
the air conditioner continues to function poorly, please stop the air
conditioner immediately and contact
$&352
’s authorized local service
center.
4.2 Error Code
①
. If abnormal things (for example, awful smell) occur, please stop the unit
immediately and disconnect power. Then contact
$&352
’s authorized service
center. If the unit continues to run in abnormal situations, it may get damaged
and cause electric shock or fire hazard.
②
. Do not repair the air conditioner by yourself. Improper maintenance will cause
electric shock or fire hazard. Please contact
$&352
’s authorized service center
and send for professional service staff to repair.
If the display panel or wired control displays an error code, please refer to the
error code meaning stated in the following table.
No. Error code
Error
1
E1
Compressor high pressure protection
2
E4
Compressor air discharge high-temperature protection
3
E3
Compressor low pressure protection, refrigerant lack
protection and refrigerant collecting mode
4
F2
Condenser temperature sensor error
5
F3
Outdoor ambient temperature sensor error
6
F4
Discharge temperature sensor error
7
F6
ODU tube temperature sensor error
8
EE
ODU memory chip error
9
PF
Electric box sensor error
10
H3
Compressor overload protection
11
H4
Overload
12
H5
IPM protection
13
H6
DC fan error