Owner's Manual 

Original Instructions 

Air Conditioners 

DC Inverter 

X-

Series for R410A Unitary 

Split Air Conditioner 

Models: 

Outdoor Unit 

$8':$'8

 

$8':$'8

 

Thank you for choosing AC Pro air conditioners. Please read this 

Owner's Manual carefully before operation and retain it for future 

reference.

Содержание AUD36W/A-D

Страница 1: ...onditioners DC Inverter X Series for R410A Unitary Split Air Conditioner Models Outdoor Unit 8 8 8 8 Thank you for choosing AC Pro air conditioners Please read this Owner s Manual carefully before ope...

Страница 2: ...and preheat the unit in advance before reusing it 3 Please properly select the model according to actual using environment otherwise it may impact the using convenience 4 This product has gone through...

Страница 3: ...to 352 Exception Clauses Manufacturer will bear no responsibilities when personal injury or property loss is caused by the following reasons 1 Damage the product due to improper use or misuse of the p...

Страница 4: ...or Code 30 4 3 Unit Maintenance 31 4 4 Notice on Maintenance 33 4 5 After Sales Services 38 This marking indicates that this product should not be disposed with other household wastes To prevent possi...

Страница 5: ...l instructions packaged with the kits or accessories when installing Follow all safety codes Wear safety glasses protective clothing and work gloves Use quenching cloth for brazing operations Have fir...

Страница 6: ...n materials including nails metal or wooden parts and plastic packing material must be treated in a safe way 1 Please install according to this instruction manual Installation must be performed in acc...

Страница 7: ...not operate the air conditioner with wet hands Do not wash or sprinkle water on the air conditioner otherwise malfunction or electric shock will occur 15 Do not dry the filter with naked flame or an a...

Страница 8: ...he outdoor unit from small animals because they may damage the electric components and cause malfunction of the air conditioner 1 If wired control is to be used it should be connected first before pow...

Страница 9: ...me Appearance Q ty Usage 1 1 Copper Pipe Connector Liquid Line 2 1 3 Installation 3 1 Installation Preparation 3 1 1 Selection of Installation Location The unit must be installed where strong enough t...

Страница 10: ...that may obstruct the air inlet and outlet 4 The installation location should be able to withstand the weight and vibration of outdoor unit and allow the installation to be carried out safely 5 Avoid...

Страница 11: ...A B C D E G AUD60W A D U 42 3 4 16 7 8 53 3 4 24 1 2 15 1 2 14 1 2 3 1 3 Diagram of Unit Installation Space and Location 1 Diagram of installation space and location for outdoor unit Notice for best p...

Страница 12: ...DC Inverter X Series for R410A Unitary Split Air Conditioner 8 1 When one outdoor unit is to be installed A E inches a b c d e B 4 A B C 12 4 4 B E 4 40 A B C E 12 6 6 40 D 40 Service Clearance 30...

Страница 13: ...installed side by side Unit mm inches A E Hb Hd H inches a b c d e A B C 12 12 40 A B C E 12 12 40 40 D 78 D E 78 40 B D Hb Hd Hd H 12 78 Hb Hd Hd 1 2H 12 78 1 2H Hd H 12 78 B D E Hb Hd Hb 1 2H 12 78...

Страница 14: ...itAir Conditioner 10 3 When outdoor units are installed in rows Unit mm inches Hb H inches Hb 1 2H B 10 1 2H Hb H B 12 Hb H Prohibited 4 When outdoor units are installed one above another Unit inches...

Страница 15: ...it and the installation base 4 When the outdoor unit is in heating or defrosting it needs to drain water When installing the drain pipe plug the accompanied drainage connector to the drainage hole on...

Страница 16: ...d outdoor units feet Liquid pipe Gas pipe AUD36W A D U AUD60W A D U 3 8 3 4 98 4 49 2 Connection pipe should adopt water proof insulating material Its wall thickness should meet local code The longer...

Страница 17: ...the heat insulating pipe back on the pipeline and fix it with adhesive tape 3 2 2 4 Connection Pipe Of The Units Connect the pipe to the unit Please follow the instructions stated in the figures belo...

Страница 18: ...nch Tightening torque ft lb 1 4 11 15 3 8 20 29 1 2 33 40 5 8 44 47 3 4 51 55 7 8 59 62 3 2 2 5 Sealing of the Knock off Hole As for the built in valve model during the installation process for connec...

Страница 19: ...e switch at the high pressure side of the manifold valve assembly should be kept closed otherwise evacuation would fail 5 The evacuation duration depends on the unit s capacity generally Model Time mi...

Страница 20: ...rigerant amount for extra pipe AUD36W A D U AUD60W A D U 24 6 31 2 32 oz per Ft 3 2 5 Installation of Drain Pipe 3 2 5 1 Outdoor Side Drainage Pipe 1 If the outdoor unit is underneath the indoor unit...

Страница 21: ...tdoor unit is above the indoor unit arrange the pipeline according to the following diagram 1 Wind the insulating tape from bottom to top 2 The whole pipeline should be wound together to avoid water r...

Страница 22: ...effectively fixed The external power cord the temperature controller wire and outdoor unit can t directly contact any hot objects For example they must not contact chimney pipes warm gas pipes or othe...

Страница 23: ...1Ph 60Hz 45 45 35 3 3 3 Connection of Power Cord and Temperature Controller Wire 1 For solid wires as shown below 1 Use wire cutters to cut off the wire end and then peel away about 1 of the insulati...

Страница 24: ...wire clamps as shown in the following figure Before working please check whether the units are powered on Wrong wire connection may burn the electrical components Connect the wires firmly to the wirin...

Страница 25: ...nes with small clamps Use screws to tighten up the temperature controller wires and power cords of the units on the terminal board Wrong connection may lead to fire hazard If the temperature controlle...

Страница 26: ...emove the big handle front panel of the outdoor unit and insert one end of the temperature controller cord and the power cord to the terminal board Single phase unit AUD36W A D U Heat Pump Cooling onl...

Страница 27: ...produce noise Did you do water leakage test Cooling capacity may become unsatisfactory Is the unit well insulated from heat Condensate water drops may occur Does water drainage go well Condensate wate...

Страница 28: ...en 4 The inside of the unit should be clean Take irrelevant objects out if there is any 5 After checking re install the front side plate Operation after connecting the power 1 If all the above works a...

Страница 29: ...ng example 3 6 2 Set Defrost Mode The second dip switch is selecting the defrost mode The second dip switch is used to change the defrost setting factory default setting is standard defrost Under extr...

Страница 30: ...output and ensure reliable operation in a short time so as to meet the user s demand for the indoor temperature to quickly reach the set temperature Energy saving mode is achieved by setting the cond...

Страница 31: ...us functions After switching to 08 short press SW2 or SW3 to enter the refrigerant recovery control mode ON means open OF means close And then short press SW1 to save During debugging if no operation...

Страница 32: ...failure Restart after power is resumed Power plug is loose Re insert the power plug Remote control has low battery Replace the batteries Bad cooling or heating effect Air inlet and outlet of the units...

Страница 33: ...le About 30s later the purr of the unit becomes low About 20s after the unit first enables the heating mode or there is refrigerant brushing sound when defrosting under heating It s the sound of 4 way...

Страница 34: ...c shock or fire hazard Do not repair the air conditioner by yourself Improper maintenance will cause electric shock or fire hazard Please contact 352 s authorized service center and send for professio...

Страница 35: ...8 Pd Sensor connection protection 29 PE Temperature drift protection 30 PL Bus low voltage protection 31 PH Bus high voltage protection 32 PU Charge loop error 33 PP Input voltage error 34 ee Drive me...

Страница 36: ...periodically clean it once at least in every two months Clean the dust and sundries on the surface of the heat exchanger with dust collector and nylon brush if there s compressed air source use the c...

Страница 37: ...be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area around the workspace shall be sectioned off Ensure that the conditions within the area have bee...

Страница 38: ...hall include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfacto...

Страница 39: ...ment Intrinsically safe components do not have to be isolated prior to working on them 4 4 3 Repair to Intrinsically Safe Components Do not apply any permanent inductive or capacitance loads to the ci...

Страница 40: ...w up leak test shall be carried out prior to leaving the site 4 4 6 Decommissioning Before carrying out this procedure it is essential that the technician is completely familiar with the equipment and...

Страница 41: ...d emptied of refrigerant The label shall be dated and signed 4 4 8 Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all ref...

Страница 42: ...acceptable level to make certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only el...

Страница 43: ...0DWHULDO 6XSSO QF GED 3UR Add 11700 Industry Ave Fontana CA 92337 USA Tel 1 951 360 0630 www acpro com...