ACPro 2PAMSH09A-17 Скачать руководство пользователя страница 10

Page 7

Special Functions

Refrigerant Leakage Detection 

When refrigerant leakage is detected, the indoor 

unit will display “EC” code or flash LEDs 

(depending on model).

Louver Angle Memory Function

The minimum and maximum angle of the 

horizontal louver is fixed. The unit has a memory 

function and will return to the last position 

selected. Never adjust the horizontal louver 

angle manually. The louver angle memory 

function does not apply when TURBO function 

or manual control is selected.

Additionally, it is strongly suggested that the 

opening of the horizontal louver not be set too 

small in case condensation forms and drops 

from the horizontal louver.

Auto-restart Function

In the event of a power interruption such as a 

blackout, once power is restored, the unit will

restart automatically with all the previous 

settings preserved by the memory function.

Self Clean Function

• Airborne bacteria uses the moisture on the 

indoor heat exchanger to grow. Regular drying 

of the exchanger prevents this growth. By simply 

pressing the SELF CLEAN button, the system 

will automatically manage the process. This 

cleaning action may be done as frequently as 

desired.

• For cooling models, only the indoor fan is active 

in low speed for 30 minutes and the unit turns off 

automatically once self clean session is 

complete.

• For cooling and heating models, the unit will 

operate in the following sequence:

  Fan mode at Low fan speed 

 

 Heating 

operation with Low fan speed 

 

 Fan operation 

     Stop operation 

 

Turn Off.

NOTE:

• This function can only be activated in COOLING 

or DRY mode.

• It is recommended that the air conditioner be run 

in the cooling operation for approximately 30 

minutes before activating SELF CLEAN function.

• Pressing the SELF CLEAN or ON/OFF button 

again during the cleaning cycle will cancel the 

operation and turn the unit off.

 

Mute Operation

Pressing the LED button on the remote control 

can turn off the indoor screen display and also 

turn of the Air Conditioner buzzer to create a 

quieter environment.

Содержание 2PAMSH09A-17

Страница 1: ...oner please read this manual carefully and keep it for future reference USER MANUAL SINGLE ZONE DUCTLESS MINI SPLIT SYSTEM 115V SYSTEMS 2PAMSH09A 17 2PAMSH12A 17 2 208 230V Systems 2PAMSH09B 17 2PAMSH...

Страница 2: ......

Страница 3: ...uthorized service technician or certified HVAC contractor for installation of this unit Contact an authorized service technician or certified HVAC contractor for repair or maintenance of this unit Thi...

Страница 4: ...inlet and outlet vents Never attempt to repair relocate or modify the air conditioner yourself Always contact your qualified service provider if required Do not operate your air conditioner in a wet e...

Страница 5: ...n Never allow the air conditioner to run for too long with the doors or windows open or if the humidity is very high If the air conditioner is to be used in conjunction with other heaters the air shou...

Страница 6: ...ng operation Displays when anti cold air feature is activated under heating mode Displays during self clean operation if applicable Displays under 46 F 8 C heating operation if applicable Page 3 1 Par...

Страница 7: ...e unit must be turned off before operating the manual control button If the unit is operational continue pressing the manual control button until the unit is off 1 Open and lift the front panel up to...

Страница 8: ...fingers into the panel of the blower and suction side The high speed fan inside may cause injury Do not operate the air conditioner for long periods with the air flow direction set downward in cooling...

Страница 9: ...DRYING operation The temperature is regulated while dehumidifying by cycling on and off of the cooling operation or fan only The fan speed in DRYING mode is LOW HEATING operation units with Heat Pump...

Страница 10: ...es the moisture on the indoor heat exchanger to grow Regular drying of the exchanger prevents this growth By simply pressing the SELF CLEAN button the system will automatically manage the process This...

Страница 11: ...Page 8 CAUTIONS Cleaning the Unit Wipe the unit with a soft dry cloth only If the unit is very dirty wipe it with a cloth soaked in warm water Cleaning the Air Filter A clogged air filter reduces the...

Страница 12: ...N Care and Maintenance cont Page 9 Preparation for Extended Non Operation If you plan to idle the unit for a long time perform the following 1 Clean the indoor unit and filters 2 Operate the fan for a...

Страница 13: ...ay not indicate malfunction Before calling for service please review the chart below NOTE A highly recommended troubleshoot for any issue in general consists of turning off unit and powering the syste...

Страница 14: ...the chart below Page 11 certified HVAC contractor If the problem persist even after performing these checks or diagnostics immediately stop operation and contact a certified HVAC contractor Be sure to...

Страница 15: ......

Страница 16: ...sport Damages caused by improper installation usage or insufficient AC supply voltage Incorrectly matched systems or damage from modification or incorporation with other products Units moved from thei...

Отзывы: