Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
16500021
October 2012
©2012 ACP Inc.
2
Illustration
Component
Testing
Results
Thermal cutout
Disconnect all wires from TCO.
Measure resistance across terminals.
Cavity TCO ...........................................
Magnetron TCO ....................................
Closed at 50ºC (122ºF) and
Opens at 85ºC (185ºF)
Closed at 115ºC (249ºF) and
Opens at 160ºC (320ºF)
Diode
Discharge Capacitor
Remove diode lead from capacitor and
connect ohmmeter.
Reverse leads for second test.
Infinite resistance should be
measured in one direction and 50K
Ω
or more in the opposite direction.
NOTE:
Ohmmeter must contain a
battery of 6 volts minimum.
Capacitor
Discharge Capacitor
Remove wires from capacitor terminals
and connect ohmmeter, set on highest
resistance scale to terminals.
Also check between each terminal and
capacitor case.
Between Terminals: Meter should
momentarily deflect towards zero
then return to over 5 M
Ω
. If no
deflection occurs, or if continuous
deflection occurs, replace capacitor.
Terminal to Case: Infinite resistance
Magnetron
Discharge Capacitor
Remove wires from magnetron and
connect ohmmeter to terminals. Also
check between each terminal and
ground.
Between Terminals: Less than 1
Ω
Each terminal to ground measures
Infinite resistance.
Note:
This test is not conclusive. If
oven does not heat and all other
components test good replace the
magnetron and retest.
Blower motor
Remove all wires from motor.
Measure resistance across coil .............
Approximately 160
Ω
Stirrer motor
Remove all wires from motor.
Measure resistance across terminals ....
Approximately 14.7K
Ω
Secondary
Filament
Primary
Transformer
Discharge Capacitor
Remove all wires from terminals.
Measure resistance from:
Primary ................................................
Filament ...............................................
Secondary to Ground screw on
transformer stack .................................
Less than <1
Ω
Less than <1
Ω
Approximately 130
Ω
Lamp and receptacle
Test continuity of receptacle terminals.
Indicates continuity with bulb
installed.
Wire Harness
Test continuity of wires
Indicates continuity