International Commercial Microwave-Technical Information 

October 2012 

 

16500021 

©2012 ACP Inc.

 

1

230 VAC, 50 Hz model 

RCS511DS 

P2001106M 

 

RCS511DS 

P2001112M 

 

  Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or 

repair of this unit. 

  Refer to Service Manual for installation, operating, testing, troubleshooting, and disassembly instruction. 

CAUTION

!

 

All safety information must be followed as provided in Service Manual. 

!

WARNING

 

To avoid the risk of electrical shock, personal injury or death; disconnect power to oven and discharge capacitor 
before servicing, unless testing requires power. 

Models 

RCS511DS  

Power Source

 

 

Voltage AC 

230 VAC 

Amperage (Single Unit) 

15 A 

Frequency 

50 Hz 

Single Phase, 3 wire grounded 

Receptacle 

CEE 7/7 Schuko 

Plug 

CEE 7/7 Schuko 

Power Output 

 Microwave

 

 

Nominal microwave energy (IEC705) 

1000 Watts 

Minimum temperature rise (

T) 

10ºF / 5ºC 

Operating Frequency 

2450 MHz 

Power Consumption

 

 

Microwave only 

1500 Watts 

Dimensions 

 

Cabinet (in cm) 

 

Width 

22" 

56 cm 

Height 

13 3/4" 

34.4 cm 

Depth 

19" 

37.9 cm 

Oven Interior (in cm)

 

 

Width 

14 1/2" 

36.8 cm 

Height 

8 1/2" 

21.6 cm 

Depth 

15 " 

38.1 cm 

Weight

 

 

Uncrated 

41 lbs. 

18.6 kg 

Features 

 

Timer 

10 minute single speed 

Power Selection 

5 Levels 

Cavity Volume 

1.2 cu. Ft. 

 

Содержание RCS511DS

Страница 1: ...ury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models RCS511DS Power Source Voltage AC 230 VAC Amperage Single Unit 15 A Frequency 50 Hz Single Phase 3 wire grounded X Receptacle CEE 7 7 Schuko Plug CEE 7 7 Schuko Power Output Microwave Nominal microwave energy IEC705 1000 Watts Minimum temperature rise T 10ºF 5ºC Operating Frequency 24...

Страница 2: ...ween Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Terminal to Case Infinite resistance Magnetron Discharge Capacitor Remove wires from magnetron and connect ohmmeter to terminals Also check between each terminal and ground Between Terminals Less than 1 Ω Each terminal to ground measures...

Страница 3: ...om Monitor Terminals 3 4 Primary Terminals 1 2 Secondary Terminals 5 6 With door closed measure resistance from Monitor Terminals 3 4 Primary Terminals 1 2 Secondary Terminals 5 6 After verifying or replacing the module re connect wires to switch and check operation of monitor circuit before operating the oven Indicates continuity Infinite Ω Infinite Ω Infinite Ω Indicates continuity Indicates con...

Страница 4: ...ture should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle remove test container...

Страница 5: ...m and Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power October 2012 16500021 2012 ACP Inc 5 ...

Отзывы: