Disassembly Procedures
To avoid the risk of electrical shock, personal injury, or death,
disconnect power to oven and discharge the capacitors before
following any disassembly procedure.
WARNING
©2010 ACP, Inc.
16400007 Rev. 0
25
Magnetron
Magnetron is located on the side of the cavity.
1. Disconnect power to oven and remove outer case,
(see "Outer Case" section).
2. Discharge high voltage capacitor, (see page 16
capacitor testing procedures).
3. Remove blower motor assembly (see "Blower Motor"
procedure).
4. Remove terminal plug from filament terminals.
5. Remove screws securing magnetron cutout bracket
to magnetron.
6. Remove screws securing magnetron to the wave
guide.
7. Replace magnetron and reverse procedure to
reassemble.
NOTE:
When replacing magnetron, make sure gasket is
in correct position and in good condition.
CAUT ION
During replacement of magnetron, be certain the R.F.
anode gasket is in place around the anode stud.
WARNING
A microwave leakage test must be performed
anytime a magnetron assembly is removed, replaced,
disassembled, or adjusted for any reason.
Blower Motor
1. Disconnect power to oven and remove outercase,
(see "Outer Case" procedure).
2. Remove outer case.
3. Disconnect wiring from blower motor, fuse block and
lower magnetron tco.
4. Remove the two screws holding the blower motor
bracket to the upper plate.
5. Remove the screw holding the blower motor bracket
to the back cover.
6. Remove the upper screw holding the high voltage
capacitor bracket.
7. Remove the lower screw holding the duct assembly.
Blower Motor ASS'Y
Suction
Guide
H.V
Transformer
H.V
Transformer
H.V capacitor
bracket
Magnetron
Magnetron