Component Testing Procedures 

 

!

WARNING

 

To avoid risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires power. 

 

16500008 

 

January 2009 

Replaces 16027357 

©2009 ACP Inc.

 

2

 

Illustration 

Component 

Test 

Results 

 

 

Thermal Cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 
Cavity Thermal Fuse ......................................
Magnetron TCO .............................................

 
 
Open at 219° F (104° C). 
Open at 280° F (138° C) and  
   closed at 180° F (82° C). 

 

Diode Assembly 

Discharge Capacitors

 

 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 

Infinite resistance should be measured 
in one direction and 50K

 or more in 

the opposite direction. 
 

NOTE:

 Test meter must contain a 

battery of 6 volts minimum. 

MT2

MT1

GA TE

 

Triac 

Disconnect wires to triac. 
 
Measure resistance from: 
MT1 to MT2 ....................................................
MT1 to Gate ....................................................
MT2 to Gate ....................................................
All terminals to ground ....................................

Caution - Do not operate oven with 
wire to terminal MT2 removed.

 

 
Infinite. 
Approximately 40 

 or more. 

Infinite. 
Infinite. 

 

Capacitor 

Discharge Capacitors

 

 
Remove wires from capacitor terminals and 
connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
 
Also check between each terminal and 
capacitor case. 

 
 

Between Terminals:

 Meter should 

momentarily deflect towards zero then 
return to over 5 M

. If no deflection 

occurs, or if continuous deflection 
occurs, replace capacitor. 
 

Terminal to Case:

 Infinite resistance. 

 

Snubber Assembly 

Disconnect wires to snubber. 
 
Measure resistance across terminals..............

 
 
Infinite. 

 

Magnetron 

Discharge Capacitors

 

 
Remove wires from magnetron and connect 
ohmmeter to terminals. Also check 
between each terminal and ground. 

Between Terminals:

 Less than 1 

 
Each terminal to ground measures 
Infinite resistance. 

NOTE:

 This test is not conclusive. If 

oven does not heat and all other 
components test good replace the 
magnetron and retest. 

 

Stirrer Motor 

Remove all wires from terminals. 
 
Measure resistance from: 

Terminal to terminal .....................................

 
 
 
Approximately 25 K

 

Blower Motor 

Remove all wires from motor. 
 
Measure resistance across coil .......................

 
 
Approximately 30 

Содержание HDC182

Страница 1: ...the risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models HDC182 HDC18SD2 CRC18T2OG2 HDC212 HDC21RB2 HDC21RT2 CRC21T2RL2 Power Source Voltage AC 230 208 VAC 230 208 VAC Amperage Single Unit 20 A 20 A Frequency 60 Hz 60 Hz Single Phase 3 wire grounded X X Receptacle 6 20R 6 20R Plug 6 20P 6 20P Power ...

Страница 2: ...e to terminal MT2 removed Infinite Approximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous def...

Страница 3: ...ed 1 3 2 Less than 1 Ω Less than 1 Ω Less than 1 Ω Less than 1 Ω 30 Ω Infinite resistance If not replace transformer Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Logic Terminal C to NO Secondary With door closed measure resistance from Terminal C to NC Monitor Terminal C...

Страница 4: ...tically switches for 208 or 230 VAC operation Control board Terminals F H Line voltage All Conditions 0 VAC Idle and Standby 0 9 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3...

Страница 5: ... container to the 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with...

Страница 6: ... To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16500008 January 2009 Replaces 16027357 2009 ACP Inc 6 12844901 DANGER HIGH VOLTAGE ...

Страница 7: ... To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power January 2009 16500008 2009 ACP Inc Replaces 16027357 7 12844901 DANGER HIGH VOLTAGE ...

Отзывы: