background image

Commercial Microwave

Technical Information

 

January 2009 

16500008 

©2009 ACP Inc. 

Replaces 16027357

 

208/230 V, 60 Hz Models 

HDC182 

P1331204M 

HDC18SD2 

P1331205M 

CRC18T2OG2  P1331206M 

HDC212 

P1331207M 

HDC21RB2 

P1331208M 

HDC21RT2 

P1331209M 

CRC21T2RL2 

P1331210M 

  Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or 

repair of this unit. 

  Refer to Service Manual RS2240002 for installation, operating, testing, troubleshooting, and disassembly 

instruction. 

CAUTION

!

 

All safety information must be followed as provided in Service Manual RS2240002. 

!

WARNING

 

To avoid the risk of electrical shock, personal injury or death, disconnect power to oven and discharge capacitor 
before servicing, unless testing requires power. 

Models 

HDC182, 

HDC18SD2, 

CRC18T2OG2 

HDC212, 

HDC21RB2, 

HDC21RT2, 

CRC21T2RL2 

Power Source

 

 

 

Voltage AC 

230/208 VAC 

230/208 VAC 

Amperage (Single Unit) 

20 A 

20 A 

Frequency 

60 Hz 

60 Hz 

Single Phase, 3 wire grounded 

Receptacle 

6-20R 

6-20R 

Plug 

6-20P 

6-20P 

Power Output

 

 

 

Nominal microwave energy (IEC705) 

1800 Watts 

2100 Watts 

Minimum temperature rise (

T) 

18º F / 10º C 

21º F / 11.5º C 

Operating Frequency 

2450 MHz 

2450 MHz 

Power Consumption

 

 

 

Cook Condition Microwave 

3450 Watts 

3450 Watts 

Dimensions 

 

 

Cabinet 

 

 

Width 

16 5/8" 

16 5/8" 

Height 

13 3/16" 

13 3/16" 

Depth 

21 9/16" 

21 9/16" 

Oven Interior

 

 

 

Width 

13" 

13" 

Height 

6 7/8" 

6 7/8" 

Depth 

12" 

12" 

Weight

 

 

 

Crated 

74 lbs. 

74 lbs. 

Uncrated 

68 lbs. 

68 lbs. 

 

Содержание HDC182

Страница 1: ...the risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models HDC182 HDC18SD2 CRC18T2OG2 HDC212 HDC21RB2 HDC21RT2 CRC21T2RL2 Power Source Voltage AC 230 208 VAC 230 208 VAC Amperage Single Unit 20 A 20 A Frequency 60 Hz 60 Hz Single Phase 3 wire grounded X X Receptacle 6 20R 6 20R Plug 6 20P 6 20P Power ...

Страница 2: ...e to terminal MT2 removed Infinite Approximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous def...

Страница 3: ...ed 1 3 2 Less than 1 Ω Less than 1 Ω Less than 1 Ω Less than 1 Ω 30 Ω Infinite resistance If not replace transformer Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Logic Terminal C to NO Secondary With door closed measure resistance from Terminal C to NC Monitor Terminal C...

Страница 4: ...tically switches for 208 or 230 VAC operation Control board Terminals F H Line voltage All Conditions 0 VAC Idle and Standby 0 9 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3...

Страница 5: ... container to the 1000 ml line with cool tap water NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with...

Страница 6: ... To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power 16500008 January 2009 Replaces 16027357 2009 ACP Inc 6 12844901 DANGER HIGH VOLTAGE ...

Страница 7: ... To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power January 2009 16500008 2009 ACP Inc Replaces 16027357 7 12844901 DANGER HIGH VOLTAGE ...

Отзывы: