Component Testing Procedures 

 

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor  
before servicing, unless testing requires it. 

 

16500038 

 

July 2012 

 

©2012 ACP, Inc. 

 

Illustration 

Component 

Testing  

Results 

 

 

Thermal Cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 

Cavity Thermal Fuse ...................................  
Magnetron TCO ...........................................  

 
 
Open at 219° F (104° C). 
Open at 280° F (138° C) and  
  closed at 180° F (82° C). 

 

Diode Assembly 

Discharge Capacitors

 

 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 

Infinite resistance in one direction 
and 50K

Ω or more in the opposite 

direction. 
 

NOTE:

 Analog meter must contain a 

battery of 6 volts minimum. 

 

MT2

MT1

GA TE

 

Triac 

Disconnect wires to triac. 
 
Measure resistance from: 

MT1 to MT2 .................................................  
MT1 to Gate ................................................  
MT2 to Gate ................................................  
All terminals to ground .................................  

Caution - Do not operate oven with 
wire to terminal MT2 removed.

 

 
Infinite. 
Approximately 40 

Ω or more. 

Infinite. 
Infinite. 

 

Capacitor Doubler 

Discharge Capacitors

 

 
Remove wires from capacitor terminals and 
connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
 
Also check between each terminal and 
capacitor case. 

 
 

Between Terminals:

 Meter should 

momentarily deflect towards zero 
then return to over 5 M

Ω. If no 

deflection occurs, or if continuous 
deflection occurs, replace capacitor. 
 

Terminal to Case:

 Infinite 

resistance. 

 

Snubber Assembly 

Disconnect wires to snubber. 
 
Measure resistance across terminals.............  

 
 
Infinite. 

 

Magnetron 

Discharge Capacitors

 

 
Remove wires from magnetron and connect 
ohmmeter to terminals. Also check 
between each terminal and ground. 

Between Terminals:

 Less than 1 

Ω. 

 
Each terminal to ground measures 
Infinite resistance. 

NOTE:

 This test is not conclusive. If 

oven does not heat and all other 
components test good replace the 
magnetron and retest. 

 

Blower Motor 

Remove all wires from motor. 
 
Measure resistance across coil .......................  

 
 
Approximately 30 

Ω. 

 

Antenna motor 

Remove all wires from motor. 
 
Measure resistance across terminals..............  

 
 
Approximately 3.4 K

Ω. 

Wire Harness 

 

Test continuity of wires ...................................  Continuity. 

Содержание HDC12A2

Страница 1: ... provided in Service Manual W ARNING To avoid the risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires it Models HDC12A2 MDC12A2 Power Source Voltage AC 120 VAC Amperage Single Unit 20 A Frequency 60 Hz Single Phase 3 wire grounded X Receptacle 5 20R Plug 5 20P Power Output Nominal microwave energy IEC705 1200 W...

Страница 2: ...ely 40 Ω or more Infinite Infinite Capacitor Doubler Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace capacitor Term...

Страница 3: ...onnect wires to switch With door open measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Terminal C to NO Logic Terminal C to NO Secondary With door closed measure resistance from Terminal C to NC Monitor Terminal C to NO Primary Terminal C to NO Logic Terminal C to NO Secondary Door Closed Primary Logic C NC NO C C NO Secondary Monitor Continuity Infinite Infinite Infinite ...

Страница 4: ...ls T1 WH J2 3 RD Control board Terminals E1 RD E4 PK Line voltage All Conditions 0 VAC Idle and Standby 0 2 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3 Replace HV LV Board F4 Replace HV LV Board F5 Replace Touch Panel F6 Replace HV LV Board Usage Test The ...

Страница 5: ...ater temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 5 At end of the cycle remove te...

Страница 6: ...iagrams To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires it 16500038 July 2012 2012 ACP Inc 6 120043101 DANG ER HIGH VOLTAGE ...

Страница 7: ...iagrams To avoid risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires it July 2012 16500038 2012 ACP Inc 7 20043101 DANG ER HIGH VOLTAGE ...

Отзывы: